2NM/2NX/2NY/2NZ/2P0/2P6
1-4-47
2. DP-scanning
Defective part
Check description
Corrective Action
1
Original document
Verify the sides of the original
document.
If the sides of the original document are
reversed, place the original document properly.
2
Contact glass assy Check the location the contact
glass is mounted.
Re-mount the contact glass if it is hanged off.
3
FFC cable CCD
Check the FFC cable between
the CCD and control PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if it its connection is
loose. Or, if conduction is lot, replace the wire.
4
Home position sen-
sor
Check the location the home
position sensor is mounted.
Re-mount the home position sensor if it is
hanged off.
5
Scanner drive belt
Check that the scanner drive belt
is loosely mounted.
If the scanner drive belt is loosely mounted,
secure the screws.
6
Scanner drive gear Check that the scanner drive
gear is loosely mounted.
If the scanner drive gear loosely mounted,
secure the screw.
7
CCD PWB
The CCD PWB is defective.
Replace the ISU and perform U411.
(see page 1-3-54)
8
Control PWB
The control PWB is defective.
Replace the control PWB.(see page 2-2-12)
Summary of Contents for P-4030 MFP
Page 7: ...This page is intentionally left blank ...
Page 13: ...This page is intentionally left blank ...
Page 19: ...2NM 2NX 2NY 2NZ 2P0 2P6 5 Installation Guide PF 320 Paper Feeder ...
Page 55: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 2 24 This page is intentionally left blank ...
Page 386: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 100 This page is intentionally left blank ...
Page 486: ...Installation Guide PF 320 Paper Feeder Installation Guide ...
Page 487: ...PF 320 㾌㙼 㾌㙼 PF 320 PF 320 PF 320 㪧㪝㪄㪊㪉㪇 㪧㪝㪄㪊㪉㪇䈱 㪧㪝㪄㪊㪉㪇G 㾌 㾌 PF 320 PF 320 ...