2NM/2NX/2NY/2NZ/2P0/2P6-1
2-3-18
When maintenance item U411 (Automatic adjustment in the scanner) is run using the specified original (P/N 302NM94340)
the following adjustments are automatically made:
Adjusting the scanner magnification (U065)
Adjusting the scanner leading edge registration (U066)
Adjusting the scanner center line (U067)
When maintenance item U411 (Automatic adjustment in the DP) is run using the specified original (P/N 302NM94330)
the following adjustments are automatically made:
* : When running this test chart, you first must clean the feed rollers with alcohol and ensure the DP width guides
are correctly positioned against the original.
Adjusting the DP magnification (U070)
Adjusting the DP leading edge registration (U071)
Adjusting the DP center line (U072)
Image quality
Item
Specifications
100% magnification
Print: ±0.8%
Copy: ±1.5%
Using DP: ±2.0%
Enlargement/reduction
Copy: ±2.0%
Using DP: ±2.5%
Lateral squareness
Copy: ±2.0mm/200mm
Using DP: ±2.5mm/200mm
Leading edge registration
Print: 1.5 mm or less
Copy: 2.5mm or less
Using DP: 2.5mm or less
Skewed paper feed
(left-right difference)
Print: 1mm /100mm or less
Copy: 1mm /100mm or less
Using DP: 1.5mm /100mm or less
Lateral image shifting
Print: 2.0 mm or less
Copy: 3.0mm or less
Using DP: 3.0mm or less
Summary of Contents for P-4030 MFP
Page 7: ...This page is intentionally left blank ...
Page 13: ...This page is intentionally left blank ...
Page 19: ...2NM 2NX 2NY 2NZ 2P0 2P6 5 Installation Guide PF 320 Paper Feeder ...
Page 55: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 2 24 This page is intentionally left blank ...
Page 386: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 100 This page is intentionally left blank ...
Page 486: ...Installation Guide PF 320 Paper Feeder Installation Guide ...
Page 487: ...PF 320 㾌㙼 㾌㙼 PF 320 PF 320 PF 320 㪧㪝㪄㪊㪉㪇 㪧㪝㪄㪊㪉㪇䈱 㪧㪝㪄㪊㪉㪇G 㾌 㾌 PF 320 PF 320 ...