DS1068-020B

 

 

LBT20769

 

INTRODUCTION 

 

This manual is addressed to the Users of the Intrusion Alarm System 1068 produced by Urmet S.p.A. 

 

The  document  provides  the  Customer  with  a  general  description  of  the  alarm  system,  its  main  features  and  also  contains  detailed 
instructions for proper use. 

 

 

The components and main functions of the system are certified Grade 1 (Ref. 1068/005) and Grade 2 (Ref. 1068/005), 
according to EN50131 standards.  

CONVENTIONS 

In this manual, some conventions have been used to distinguish between different types of information: 

 

    

    

              

This is the equivalent key to be pressed on the keypad. 

 

 

<Master code> 

 

 

This indicates the code to be entered using the keypad. 

<User code> 

<Installer code>

 

<Technical Manager code>

 

 

 

<Master / User code>

 

This means that either code may be entered on the keypad indifferently. 

 

 

 
 

The manual also contains symbols that provide the following information:

 

 

 

Warning!

  Warning  messages  highlight  potential  system  damage,  data  loss  or  non-compliance  with  applicable 

regulations. 

 

Notes:

 notes contain important information, which may be useful for better use of the system. 

 

This symbol indicates the compatibility with EN50131 grade 1 certification. 

The overall certification of the system is equal to the minimum certification of the devices installed and the functions 
enabled. 

 

 

This symbol indicates the compatibility with EN50131 grade 2 certification.  

The overall certification of the system is equal to the minimum certification of the devices installed and the functions 
enabled. 

 

 

This symbol indicates that the function or the device invalidate the EN50131 certification. 

 

Refer to the device’s installation manual. 

 

 

Summary of Contents for 1068/005

Page 1: ...005 Ref 1068 010 Ref 1068 005 Through the following QR Code it is possible to download the eventual new version of the manual Ref 1068 010 USER MANUAL http qrcode urmet com default aspx prodUrmet 1417...

Page 2: ...on 17 2 5 1 How to view system status 17 2 5 2 How to view isolated or inhibited inputs 17 2 5 3 How to examine the Alarms Memory 17 2 5 4 How to delete the Alarms Memory 17 2 5 5 How to examine the T...

Page 3: ...o program a descriptive user name 37 7 PHONE DIALER AND IP INTERFACE 38 7 1 Alarm and event notifications 38 7 2 Phone numbers and IP addresses 39 7 2 1 How to edit a phone number 39 7 2 2 Changing th...

Page 4: ...Field Test 47 9 1 7 IP interface test 47 9 1 8 Supplementary power supply battery test available only with 1068 010 control panel 47 10 SYSTEM SHEET 48 10 1 Installation details 48 10 2 Zones table 48...

Page 5: ...e Master User code This means that either code may be entered on the keypad indifferently The manual also contains symbols that provide the following information Warning Warning messages highlight pot...

Page 6: ...on Viewing Supplied indications A Power supply Green LED Steady on mains power present Slow blinking no mains power B Notices Yellow LED Steady on in case of Alarms or Tampering Fast blinking in case...

Page 7: ...thief and emergency signalling or activation deactivation of the outputs that can be controlled In programming menu item selection deselection G Function key Home page access to the programming menu I...

Page 8: ...m condition present Off No alarm condition present Reverse On Consultation of details in progress ICON DETAILS ALARMS menu Tamper Yellow LED On At least one tamper condition present Off No tamper cond...

Page 9: ...open inputs Numbered square with white background indicates o Zone associated with the keypad not active with at least 1 input open Numbered square with a black background as in the image indicates o...

Page 10: ...ults Slow blinking open or inhibited isolated inputs B Keyhole for electronic key 1067 334 1067 335 Shaped hole for inserting the electronic key 1 4 1068 435 PROXIMITY KEY READER Figure 6 1068 435 pro...

Page 11: ...ANAGER menu by entering the access code Press to confirm 2 Select Keypad settings by pressing the key associated with the or symbol Press to confirm 3 Select LCD info by pressing the key associated wi...

Page 12: ...adequate ambient lighting conditions Backlighting will not be switched back on even if a key is pressed 2 2 DATE AND TIME SETTING In addition to being shown on the keypad in the home page date and ti...

Page 13: ...ng keys will only work if they have been previously programmed Proceed as follows to configure the function 1 Access the MASTER INSTALLER menu by entering the access code Press to confirm 2 Select Key...

Page 14: ...the MASTER INSTALLER TECH MANAGER USER menu by entering the access code Press to confirm 2 Select System status by pressing the key associated with the or symbol Press to confirm 3 Moving with associa...

Page 15: ...ompliant with EN50131 unsetting with electronic or proximity key remote unsetting via PSTN module available only with 1068 005 control panel GMS module or IP interface and radio remote control The aut...

Page 16: ...old up function has been enabled if you are threatened and forced by a criminal and your life is at risk then you can unset the intrusion alarm system while setting the hold up alarm simultaneously wh...

Page 17: ...n only be isolated if it has been programmed as such All users can isolate an input associated with their zone of competence To view addresses of isolated inputs 1 Enter the menu by entering the acces...

Page 18: ...the stored Fault events 4 Press repeatedly to go back to the upper level menu 2 5 8 How to delete the fault memory How to delete the fault memory 1 Enter the menu by entering the access code Press to...

Page 19: ...revent the setting of any zone are the following Bus failure No communication with a wired device or a communicator or lack of radio supervision Control panel tamper radio device or wired device 24 ho...

Page 20: ...the System log IMPORTANT Overriding the prevention of setting is a temporary solution to allow to set the alarm system also when conditions which may compromise efficacy are present It is advisable to...

Page 21: ...The function key of the keypad wireless keypad or remote control has been pressed Alarm System shutdown I Control panel powered only by battery below 10 5V threshold Check that the 220V voltage is pre...

Page 22: ...or failure input has been opened Faults Siren failure I A customised siren failure input has been opened Faults IDP I A call has been made to a surveillance centre via IDP numeric protocol IDP IP I A...

Page 23: ...th the 2 7Kohm resistor Tampering Maintenance M I T U The system sets to maintenance mode Tampering First Entry Last Exi I A customised first entry last exit input with at least one active assigned zo...

Page 24: ...keypad display Suggested actions Tamper I Verify that all tampers of the devices in the system are closed Tampering Technological sustained M I T U A customised technological input has been opened Ti...

Page 25: ...ill occur if an electronic or proximity key is used 3 User code This code must be enabled by the Master code and will remain valid until it is deactivated by the Master code or by a time scheduler com...

Page 26: ...d with the or symbol Press to confirm 5 Enter the Old code and press to confirm 6 Enter the New code 4 to 6 digits and press to confirm 7 Press to confirm the new code 8 Press repeatedly to go back to...

Page 27: ...low will be opened 5 2 2 How to navigate the menus The menus are organised in a tree structure i e with reciprocally nested submenus each consisting of one more items Programming is carried out using...

Page 28: ...scroll the menu to the right The symbol indicates that the menu or parameter includes a submenu with multiple choice Press the key associated with the symbol to scroll the menu to the left The symbol...

Page 29: ...interface separately M I T U System settings Submenu I Programming It allows you to configure the zones of the system the various inputs and bus peripherals the outputs of control panel and expansion...

Page 30: ...apabilities are put on hold until someone namely the Master User authorises them to use them Similarly the Master User can revoke the authorisation and put the capabilities back on hold at any time En...

Page 31: ...ad is used IMPORTANT The Technical Manager is automatically enabled each time the system is turned on Proceed as follows to enable the Technical Manager 1 Access the MASTER menu by entering the access...

Page 32: ...to go back to the main menu 5 4 6 How to enable remote access Enabling the remote access allows access via the Urmet secure and Urmet 1068set Apps Proceed as follows to enable remote access to the sys...

Page 33: ...ct Authorisations by pressing the key associated with the or symbol Press to confirm 4 Select Users by pressing the key associated with the or symbol Press to confirm 5 Select the desired user USXX Us...

Page 34: ...e key associated with the or symbol Press to confirm 4 Select Advanced by pressing the key associated with the or symbol Press to confirm 5 Press the key associated with the ADVANCED message on the di...

Page 35: ...stored events move down by one position as a new event is added When the System Log reaches the maximum size 1000 events each new event will be written over the oldest stored event The System Log may...

Page 36: ...Press to confirm 6 Select Event type or Date type by pressing the key associated with the or symbol to display the events according to the date or type of event Press to confirm 7 Press repeatedly to...

Page 37: ...e s you wish to associate to the selected user by pressing the key associated with the or symbol 9 Press the key associated to the ASSIGNMENT message on the display Press to confirm assigned zone NOT...

Page 38: ...p They can only be sent from the 1068 013 module IMPORTANT It is not recommended to use the 1068 458 module to make calls with the IDP protocol In fact the operation of this protocol is not guaranteed...

Page 39: ...and port 1 Access the MASTER INSTALLER menu by entering the access code Press to confirm 2 Select System Settings by pressing the key associated with the or symbol Press to confirm 3 Select Communica...

Page 40: ...type by pressing the key associated with the or symbol 8 Press the key associated with the SENDING TYPE message on the display Press to confirm Sending selected Sending NOT selected 9 Press repeatedly...

Page 41: ...play Press to confirm Associated event NOT associated event 9 Press repeatedly to go back to the upper level menu 7 3 SMS MESSAGES The 1068 series control panels can send SMS messages to the programme...

Page 42: ...ne will be rejected The control panel will send a reply text message with the received message text and OK or KO to confirm command reception EXAMPLE Command 2031 Reply 2031 OK Otherwise the reply wil...

Page 43: ...er 2 Call the control panel back within 30 seconds 3 The control panel will immediately engage the line after the first ring without counting the number of programmed rings In this manner the telephon...

Page 44: ...e 2 Remote controls Outputs 01 99 Selection of the output to be controlled the output must have zones in common with the code and must be controllable 0 1 Command 0 unset 1 set If the output is pulsed...

Page 45: ...ing all programmed inputs 7 Press to end the test 8 After the control panel has performed the test messages concerning the status of each input will be shown on the display of the keypad If the test i...

Page 46: ...to confirm 3 Select Test by pressing the key associated with the or symbol Press to confirm 4 Select Call or SMS by pressing the key associated with the or symbol Press to confirm 5 Select the number...

Page 47: ...by pressing the key associated with the or symbol Press to confirm 4 Select IP interface by pressing the key associated with the or symbol Press to confirm 5 The system will show Waiting for followed...

Page 48: ...DS1068 020B 48 LBT20769 10 SYSTEM SHEET 10 1 INSTALLATION DETAILS Installation date Last name and first name Address Phone 10 2 ZONES TABLE Zone ID Zone description Notes 1 2 3 4 5 6 7 8...

Page 49: ...DS1068 020B 49 LBT20769 10 3 TABLE OF PROGRAMMED PHONE NUMBERS ID Name Phone no 1 2 3 4 5 6 7 8 9 10 11 12...

Page 50: ...puts using text messages Send a text message to the control panel in the following format 2 nn s where nn is the two digit logical number of the controllable input s is a digit which represents the st...

Page 51: ...of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipmen...

Page 52: ...T20769 DS1068 020B URMET S p A 10154 TORINO ITALY VIA BOLOGNA 188 C Telef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Area tecnica servizio clienti 39 011 23 39 810 http www urmet com e mail inf...