DS1068-020B
45
LBT20769
9
SYSTEM TEST
9.1
PERIODICAL TESTS
It is advisable to check perfect operation of the intrusion alarm system regularly.
The main tests are:
Inputs
Outputs
Control panel Battery
Call or SMS
Push notification sending
GSM field
Radio devices (see dedicated manual)
IP interface
Supplementary power supply battery (available only with 1068/010 control panel)
Test the 1068 series system before prolonged absences, for example before the summer holidays.
9.1.1
Input test
Proceed as follows to test that the inputs work perfectly:
1.
Access the
MASTER
/
INSTALLER
menu by entering the access code. Press
to confirm;
2.
Select "
System Settings
" by pressing the key associated with the
or
symbol.
Press
to confirm;
3.
Select "
Test
" by pressing the key associated with the
or
symbol.
Press
to confirm;
4.
Select "
Inputs
" by pressing the key associated with the
or
symbol.
Press
to confirm;
5.
Press
to start the test;
6.
Perform a test by opening all programmed inputs;
7.
Press
to end the test;
8.
After the control panel has performed the test, messages concerning the status of each input will be shown on the display of the
keypad;
If the
test is successful
, a "V" sign will be assigned to the input string;
In case of
a failed test
, an "X" sign will be assigned to the input string;
9.
Press
repeatedly to go back to the upper level menu.
9.1.2
Output test
Proceed as follows to test that the outputs work perfectly:
1.
Access the
MASTER
/
INSTALLER
menu by entering the access code. Press
to confirm;
2.
Select "
System Settings
" by pressing the key associated with the
or
symbol.
Press
to confirm;
3.
Select "
Test
" by pressing the key associated with the
or
symbol.
Press
to confirm;
4.
Select "
Outputs
" by pressing the key associated with the
or
symbol.
Press
to confirm;
5.
Select the output you want to test by pressing the key associated with the
or
symbol.
6.
Press the key associated with the "OUTPUT TEST" message on the display. Press
to confirm and start the test;
Test associato
; NOT associated test
.
7.
Check the correct switching of the output;
8.
Press
repeatedly to go back to the upper level menu.