DS1068-020B
23
LBT20769
Description on
System log
Visible with
code...
Event
Icon on
keypad display
Suggested actions
Delayed intrusion
M
– I – T - U
A customised delayed input with at
least one active assigned zone
has been opened.
Alarm
---------------
Isolation
M
– I – T - U
An input has been manually
isolated by the user.
Isolated
---------------
Jamming
I
The system has detected an
interference on the radio part
Tampering
---------------
No dialogue
I
No communication with keypads,
expansions, readers, IP, GSM,
PSTN
(available
only
with
1068/005 control panel), radio
devices (supervision enabled).
Tampering
Check that the BUS devices,
radio devices and interfaces
on the control panel are
correctly connected.
Loss of mains
M
– I – T – U
Instantaneous and persistent loss
of mains (2 different messages in
the log).
---------------
Verify that:
The 220V mains power is
present
The control panel power
supply unit is working
Tamper
I
A customised tamper input has
been opened
Some inputs of BAL or double BAL
type have been unbalanced.
Tampering
Check that the BAL or double
BAL inputs are correctly
connected with the 2.7Kohm
resistors.
Tampering in 24H
I
Check that the tamper inputs are
properly grounded with the
2.7Kohm resistor.
Tampering
---------------
Maintenance
M
– I – T – U
The system sets to maintenance
mode
Tampering
---------------
First Entry/Last
Exi
I
A customised first entry/last exit
input with at least one active
assigned zone has been opened.
Alarm
---------------
Time scheduler
M
– I – T – U
The activation of the system
through the time scheduler has
been postponed manually.
Time scheduler
---------------
Communicator
progr.
I
The programming of the
communicator has been changed
---------------
---------------
Reset
I
Event generated at each restart or
reset (RESET jumper) of the
control panel
---------------
---------------
Reset
I
The system has been reset to the
factory settings.
---------------
---------------
Fire Reset
M
– I – T – U
A customised fire reset input has
been opened
---------------
Available only with
1068/010 control panel.
Restoring
I
A configuration backup has been
restored.
---------------
---------------
Update result
I
Result of FW upgrade of the
devices
---------------
Check that the arrow next to
the description is pointing
upwards (positive result). If
the arrow points down
(negative result), repeat the
system upgrade procedure.
SIM
expiration date
M
– I – T – U
The day of the set expiration date
has been reached.
---------------
Renewing or topping up your
SIM Card
Updating the expiration date
Emergency
M
– I – T – U
A customised emergency input
has been opened
The function key of the keypad,
wireless keypad or remote control
has been pressed
Alarm
---------------
Zone status
M
– I – T – U
One or more zones of the system
have been activated or deactivated
---------------
---------------