5.2.2 Various methods of displaying readings on the TCAM2
You access this operating mode using the right
bottom of the mouse. You position the cursor
either in the counter field of X or Z-axis and press
the eight bottom on the mouse.
The window with the methods of displaying will
Open.
You can change the attributes for each axis separately.
•
Absolute
Current counter value relating to the selected tool refer-
ence.
•
Difference
Current counter value relating to the selected tool refer-
ence
including
nominal values.
•
Increment
The reading is reset to 0.000.
•
Diameter
The current reading is doubled.
•
Hold
The hold function (counter stop function) is switched on.
The counter analysis continues to work in the background.
As the following examples show, the different display modes can be shown combined
with each other:
Display of the X reading with additional information
∆
Difference
display
∅
Diameter
display
red Display with hold function set (counter stop).
Display of the Z reading in increment mode.