67
Parameter
Description
Mask
Authentication
Failed And Open
The Door
On: When a person without a mask is detected, the terminal will
display a message “please wear a mask” on the screen and play this
message in audio, and the door will open.
Off: When a person without a mask is detected, the terminal will
display a message “please wear a mask” on the screen and play this
message in audio, and the door will not open.
The default value is
Off
.
Temperature
Measurement
Temperature
Measurement
Measure Forehead Temperature: The forehead temperature will
be measured.
Measure Wrist Temperature: The wrist temperature will be
measured.
Measure Forehead / Wrist Temperature: The terminal can
measure either forehead temperature or wrist temperature.
Do not need configuration. Terminal will automatically match the
temperature measurement mode when it is connected to the digital
detection module.
Authentication
Failed And Open
The Door
On: When a temperature over the preset temperature alarm
threshold is detected, the terminal will display a message “abnormal
temperature” on the screen and play this message in audio, and the
door will open.
Off: When a temperature over the preset temperature alarm
threshold is detected, the terminal will display a message “abnormal
temperature” on the screen and play this message in audio, and the
door will not open.
The default value is
Off
.
Authentication
Success At Low
Temperature
On: When a temperature below the minimum temperature of the
measurement range is detected, the terminal will display a message
“low temperature” on the screen and play this message in audio, and
the door will open.
Off: When a temperature below the minimum temperature of the
measurement range is detected, the terminal will display a message
“low temperature” on the screen and play this message in audio, and
the door will not open.
The default value is
Off
.
Temperature Unit
The options are as follows:
℃
℉
Set the temperature unit based on actual conditions.
Temperature
Measurement
Range
Value range: [30–45]; default range: [35.5–42]
Set the range based on actual conditions.
Temperature
Alarm Threshold
When a temperature over the threshold configured here is detected,
the terminal will display a message “abnormal temperature” on the
screen and play this message in audio.
Value range: [30–45]; default value: 37.3
Temperature
Alert
After this function is turned on, when body temperature is within the
range of temperature alert threshold and temperature alarm
threshold, high temperature alarm will be given to remind people to
re-detect.
The default value is
Off
.
Temperature
Alert Offset
Temperature Alert Threshold = Temperature Alarm Threshold =
Temperature Alert Offset