49
Item
Description
NOTE!
You can set this parameter only when
Exposure Mode
is not set to
Shutter Priority
and when
Image
Stabilizer
is disabled.
Slowest Shutter
Set the slowest shutter speed that the device can use during exposure.
NOTE!
You can set this parameter only when
Slow Shutter
is set to
On
.
Compensation
Adjust the compensation value as required to achieve the desired effects.
NOTE!
You can set this parameter only when
Exposure Mode
is not set to
Manual
.
Metering Control
Set the way the device measures the intensity of light.
Center-Weighted Average Metering: The device measures light mainly in the central part of images.
Evaluative Metering: The device measures light in the customized area of images.
Spot Metering: It is similar to
Evaluative Metering
but the difference is that the image brightness
cannot be improved.
Face Metering: The device adjusts the image quality in poor lighting conditions by controlling the
brightness of captured face photos in Face scene.
NOTE!
You can set this parameter only when
Exposure Mode
is not set to
Manual
. The default value is
Face
Metering
.
Face Brightness
This parameter is displayed only when
Metering Control
is set to
Face Metering
.
In
Face Metering
mode, the system adjusts the exposure based on the value of
Face Brightness
and
the face brightness in the live view so that the face brightness in the live view is within the appropriate
range (over-exposure or under-exposure may be incurred to surroundings on the images).
The value ranges from 0 to 100 and the default value is 50. A larger
Face Brightness
value indicates higher
image brightness on the device and brighter face snapshot photos.
Min. Duration(min)
This parameter is displayed only when
Metering Control
is set to
Face Metering
.
It refers to the maximum duration that the screen brightness of the device (applicable to the previous
face) can be retained after the face detection of the previous person ends and the face of the next
person is not detected. The timer is restarted each time the face detection of a person ends. After the
time expires, the device adapts to the average brightness of the current environment till the face of the
next person is detected.
The value ranges from 0 to 60 and the default value is 5.
Day/Night Mode
Keep the default value
Automatic.
Automatic: The device outputs the optimum images according to the light condition. In this mode,
the device can switch between night mode and day mode automatically.
Day: The device provides high-quality color images using the existing light.
Night: The device provides high-quality black and white images using the existing light.
Input Boolean: The device provides high-quality images by using external light.
Day/Night
Sensitivity
Light threshold for switching between day mode and night mode. A higher sensitivity means that The
device is more sensitive to the change of light and becomes more easily to switch between day mode
and night mode.
NOTE!
You can set this parameter only when
Day/Night Mode
is set to
Automatic
.
Day/Night
Switching(s)
Set the length of time before The device switches between day mode and night mode after the
conditions for switching are met.
NOTE!
You can set this parameter only when
Day/Night Mode
is set to
Automatic
.