Power Adjustment
The Intelligent Materials Database determines the appropriate laser power
based on the material type, thickness, and selected laser type. Power
adjustment enables users to fine-tune this value to accommodate deviations
in material thickness or chemical formulations.
G
Laser Enable
Disable Toggle
Buttons
Enables or disables each laser individually if more than one laser source is
available for the selected laser type.
H
Gas Assist Type
Enables selection for the type of Gas Assist to be applied. Options include
Gas
,
Air,
and
None.
If using
Coaxial Gas Assist
, or optional
Lateral Gas Assist
,
either the
Gas
or
Air
option must be selected.
If
Gas
or
Air
has been selected for any process, all processes must have one
or the other selected. If no Gas Assist is desired, the
Coaxial
or
Lateral
Gas
Assist attachment must be removed and no process can be set to use either
Gas
or
Air.
I
Gas Assist Flow
Rate
Enables target flow rate adjustment for the Gas Assist source. This option is
not available when
None
is selected for Gas Assist.
J
Kerf Width
Enables
Kerf Compensation,
which provides users the ability to compensate
for the width of a cut or mark when set to any non-zero value. Note that
Kerf
Compensation
will only be applied to shapes in the design file of the selected
process that are completely closed. Kerf compensation will not be applied to
shapes that are open, even by a small amount.
K
Repeat Count
The number of times to repeat a selected process.
L
Material Selection
Indicates the currently selected material for the current database process. The
Pencil
button launches the database’s M
aterial Selection Dialog
that
categorically lists all of the materials compatible with the current system
setup in the Intelligent Materials Database.
M
Material Thickness
Displays the thickness of the material to be processed. This information is
required for
Database Vector Cut
processes. Units are adjustable in the
Systems Configuration
Page
.
N
Autofocus
Settings
Enables or disables the Autofocus procedure before the process begins. If a
single material height is used, it is more efficient to only enable Autofocus
for the first process and leave subsequent processes disabled. In the case
shown above, Autofocus is disabled, so the system is instructed to
Stay In
Place
at the beginning of the selected process.
O
Pierce Toggle
Button
Enables piercing at the beginning of each graphical element.
Pierce
settings
can be adjusted in the
Advanced
section of the
Configuration Page
.
P
Save / Delete /
Discard Changes
Select one of these three options to:
Save
the process settings,
Delete
the
current process and move the assigned colors to the unassigned category, or
Discard
changes and return to the
System Operations
Page
.
Summary of Contents for ULTRA X6000
Page 1: ...ULTRA X6000 Laser System User Guide www ulsinc com Version 2020 06 0102...
Page 4: ...4 This page left intentionally blank...
Page 12: ...12 ULTRA X6000 Platform Side View All dimensions are indicated in inches and millimeters...
Page 19: ...19 ULS CO2 Laser Source Safety Labels...
Page 20: ...20 ULS Fiber Laser Source Safety Label...
Page 21: ...21 ULTRA X6000 Platform Safety Labels Isometric Side View...
Page 22: ...22 ULTRA X6000 Platform Safety Labels Rear View...
Page 23: ...23 ULTRA X6000 Platform Safety Labels Left View...
Page 24: ...24 Class 4 Pass Through Safety Labels...
Page 27: ...27 Meet the ULTRA X6000 Platform 3...
Page 32: ...32 This page left blank intentionally...
Page 83: ......