57
6
ADVANCED USE
57
ADVANCE
D USE
Chapter
6
6-3.
Over Print
Print data out of the range set by the connecting indicator or the M252B is identified by this
function. There are two types of over print: over status (R) and range over (U/L).
■
Over Status (R)
Printing is different according to setting of [26: Data Check ON/OFF].
When the data check is OFF, if the indicator side causes a LOAD (A/D converter input over), OFL1
(net>99999) or zero abnormality, "R" is added after printed data, and the data is not added to grand
totals/sub totals. It is not counted up either.
When the data check is ON, if the SI/F data is unstable or the weight value is negative, in addition
to the above conditions, "Err*" or "R" is added to the printed data and no unit is printed. Also, for
the displacement diagram, "R" is simply printed, and for double-size printing, "R" is added and no
unit is printed.
Example of printing with Data Check OFF
EFGHI
4
563kg
EFGHI
3
1356kgR
EFGHI
3
1356kgR
EFGHI
3
849kg
EFGHI
2
1000kg
EFGHI
1
1356kgR
EFGHI
1
150kg
Over status
Not counted up
------------------------
GT 2562kg
COUNT 4
CODE EFGHI
DATE 2000/07/04 02:36
--- GRAND TOTAL Ach ---
GT (grand total)
With the SI/F, over status is automatically sent from the indicator. With the BCD
input, over print is performed when a signal is input to pin No.46 [over input].
Point
Over status is printed because the indicator side has a problem. The problem
cannot be solved by setting on the printer side.
Attention