51
6
ADVANCED USE
51
ADVANCE
D USE
Chapter
6
Be careful when over 32 types of codes or other than 00~31 codes is selected
from front panel or option, accumulation is conducted taking items below as
selected.
Code: Code printed first after calculated GT
Code Table: Code registered in Code table 00
000005 4 100kg
000006 1 100kg
000005 3 50kg
000003 1 100kg
000005 2 100kg
000001 2 100kg
000001 1 100kg
000005 1 50kg
After calculated GT.
Accumulation is conducted
taking the code first printed
as selected.
In this case 000005 is
selected.
000032
000006
000005
000003
000005
000001
000001
000005
Input
Print direction
Example) When 000032 is selected after 32 types of code 000000~000031 were printed.
Accumulation is conducted
taking the Code registered
in Code table as selected.
In this case, ABCDE is
selected.
Input
Print direction
Example) When 32 in Code Table is selected.
ABCDE 2 100kg
FGHIJ 1 100kg
KLMNO 3 50kg
PQRST 1 100kg
ABCDE 1 50kg
KLMNO 2 100kg
UVWXYZ 2 100kg
UVWXYZ 1 100kg
KLMNO 1 50kg
32
06
05
03
00
05
01
01