5.FUNCTION SETTINGS
66
5-14. Restriction of the Tare Subtraction Function
It can be restricted the function of digital tare subtraction or one touch tare subtraction.
a) One-touch tare subtraction
(Select from Regularly / In stable mode)
acceptance condition
It displays the timing of the Tare subtraction.
b) Range of tare subtraction
(Whole range or from 0
<
Tare
≦
Capacity)
c) Tare Weight display with
(Select from Valid / Invalid)
the
key
If it is set to be valid, the Tare Weight is displayed
at the weight display section by pressing
.
d) Digital tare subtraction
(Select from Valid / Invalid)
expansion
(Prohibition of Tare Weight and digital tare subtraction
ON/OFF when one-touch tare subtraction is working.)
Select valid for inhibiting Tare Weight and digital tare
subtraction ON/OFF when tare subtraction is in operation.
Operation
a), b), c), d)
1) Select setting mode 4.
2) Put restrictions on the above four items.
(9-Restriction of the Tare Subtraction Function)
0
0
→
→
→
F
CNG/ENT
CNG/ENT
4
SP1
One-touch Tare subtraction
1 : Accept only at stable time
0 : Accept regularly
1 : Valid
0 : Invalid
Range of Tare subtraction
1 : 0
<
Tare
≦
Capacity
0 : Total range
Prohibition of Tare Weight
1 : Valid
0 : Invalid
Tare Weight display with
the
key
0
and digital tare subtraction
ON/OFF when one-touch
tare subtraction is working.
acceptance condition
→
→
→
9
FINAL
CNG/ENT
CNG/ENT