6.DISCHARGING CONTROL MODE
85
Setting compensation parameter
a) AFFC.
Set the regulated value to avoid the compensation value
becomes extremely large (or small).
(Input range / 0 ~ 99999)
b) AFFC. ON/OFF
Selection of AFFC.
When CC-Link is installed, writing of free fall compensation
data can be prohibited, at the time of writing in the exclusive
data area.
(Select from OFF, ON, ON
(Communication OP invalid)
)
c) Average count of AFFC.
Number of weighing value for calculating the average of
compensation.
(Input range / 1 ~ 9)
d) AFFC. coefficient
Setting for avoiding fluctuations of the compensation value be
computed by multiplying the compensation and the coefficient
of not more than 1.
Operation
(Select from 1, 3/4, 2/4 or 1/4)
a)
1) Select setting mode 1.
2) Input the AFFC.. (7-Auto Free Fall Compensation Regulation)
b), c), d)
1) Select setting mode 2.
2) Set AFFC. ON/OFF, average count of AFFC. and AFFC. coefficient.
(3-Weighing Function 3)
→
→
→
F
CNG/ENT
CNG/ENT
1
UPPER
→
→
→
Auto Free Fall Compensation Regulation
(0 ~ 99999)
7
OVER
CNG/ENT
CNG/ENT
→
→
→
F
CNG/ENT
CNG/ENT
2
LOWER
3 : AFFC. coefficient
1/4
2 :
〃
2/4
1 :
〃
3/4
0 :
〃
1
Average count of AFFC.
(1 ~ 9)
→
→
→
CNG/ENT
CNG/ENT
3
NEAR Z
.
2 : AFFC.
ON
(Communication OP invalid)
1 :
〃
ON
0 :
〃
OFF
ZERO