3.METHODS OF SETTING
21
(Example 3) For setting the 1/4 scale division display to OFF (Setting from choices)
This operation can be performed by the following procedure.
* However, it is assumed that setting mode 3 has already been selected.
1) Select the setting item.
(Since the setting item number of the 1/4 scale division display is 7, press the
key.)
2) Press the
key.
3) Move with the
key until the digit you want to set blinks. (
)
→
→
→
7
OVER
CNG/ENT
CNG/ENT
ZERO
ZERO
ZERO
7
OVER
Present setting value
Setting mode number
Setting item number
The setting mode number, setting
item number, and present setting
value are displayed.
kg
,
CNG/ENT
Present setting value
Setting mode number
Setting item number
The highest digit of the setting
value blinks.
kg
,
ZERO
ZERO
ZERO
ZERO
kg
,
Not defined
Setting mode number
Setting item number
1/4 scale division display
Decimal place
Display frequency
ZERO
Subdisplay selection
Every time the key is pressed,
the blinking digit moves to the lower one.