18.THE LIST OF INITIAL SETTING VALUE
176
18. THE LIST OF INITIAL SETTING VALUE
* Initial value
: Factory-shipped values.
* LOCK 1
: Changing of setting values is inhibited by the software switch (Setting Value
LOCK in setting mode 4) (stored in the SRAM).
* LOCK 2
: Changing of setting values is inhibited by the software switch (Setting Value
LOCK in setting mode 4) (stored in the NOV RAM).
* LOCK SW
: Changing of setting values is inhibited by the LOCK switch on the rear panel
(stored in the NOV RAM).
* Display
: Setting cannot be changed.
18-1. Setting Mode 0
18-2. Setting Mode 1
→
→
→
0
F
CNG/ENT
CNG/ENT
Setting item
Initial
value
LOCK 1
(SRAM)
LOCK 2
(NOV.RAM)
LOCK SW
(NOV.RAM)
Display
1
Upper Limit
000.00
◎
2
Lower Limit
000.00
◎
3
Near Zero
000.00
◎
4
Set Point 1
000.00
◎
5
Set Point 2
000.00
◎
6
Compensation
00.00
◎
7
Over
0.00
◎
8
Under
0.00
◎
9
Final
000.00
◎
→
→
→
F
CNG/ENT
CNG/ENT
1
UPPER
Setting item
Initial
value
LOCK 1
(SRAM)
LOCK 2
(NOV.RAM)
LOCK SW
(NOV.RAM)
Display
1
Comparison Inhibit Time
0.50
◎
2
Judging Time
1.50
◎
3
Complete Output Time
3.00
◎
4
Adjust Feeding Time
1.00
◎
5
Auto Zero Times
01
◎
6
Judging Times
01
◎
7
Auto Free Fall Compensation
Regulation
098.00
◎
8
Analog Filter
2
◎
9
Tare Weight
000.00
◎