3.26.9 Fault Trace Configuration
Error tracing and logging can be configured separately for all components, i. e.
the services and applications running on the OpenScape Desk Phone. The
resulting files can be viewed in the WBM web pages over the
Download
links.
The
File size (bytes)
parameter sets the maximum file size. When it is reached,
the data is saved as old file, and a new file is generated. From then on, the trace
data is written to the new file. When the maximum file size is reached again, the
data is saved as old file once more, thereby overwriting the previous old file. The
default value is 65536.
INFO:
The absolute maximum file size is 6 290 000 bytes.
However, on OpenScape Desk Phones, a maximum size no
greater than 1000 000 bytes is recommended due to the amount
of available memory.
The
Trace timeout (minutes)
determines when to stop tracing. When the timeout
is reached, the trace settings for all components are set to OFF, but ERROR and
STATUS messages are still written to the trace file ad infinitum. When the trace