Alarm Operation
Emergency Call Alarm
For more information, refer to the Configuration Manual, Unify OpenScape WLAN Phone WL4.
Emergency Call Alarm
The emergency call alarm is triggered when a user calls an external or internal number specified
in the system as emergency number. When an emergency call alarm is made, the default
Emer-
gency call alarm
text is shown on the handset display.
Emergency call alarm as well as the alarm text are configured by the system administrator. For
the details, please refer to the Configuration Manual, Unify OpenScape WLAN Phone WL4.
Alarm with Additional Information
Information about the approximate location of the handset is automatically sent along with an
alarm. Positioning information is obtained using different location services and includes the fol-
lowing:
• The four latest locations from each location type (BLE).
• The two latest AP locations.
For the details on location services, please refer to the
on page 45.
It is also possible to add the data, for example a number, to all type of alarms. Please refer to the
on page 44.
Associated Access Point (AP) Location
This function is used together with an alarm. The AP communicates to the handset where the
handset is located for the time being. This gives a fair indication of the location.
An approximate location of the handset is added to alarms sent from the handset. The handset
sends the current and previous AP location to indicate where the alarm was activated.
Alarm with Data
The data can be defined and stored manually by the user using the
Edit alarm data
function in
the
Services
on page 55). The stored data is added to all
types of alarms at transmission.
Acoustic Location Signal
All types of alarm can be followed by an Acoustic Location Signal (ALS). The ALS is an acoustic
signal from the handset that sounds for a predefined period of time to make it possible to by ear
locate the person that has initiated the alarm.
The signal is silenced by pressing the
Mute
button on the handset.
NOTICE:
The ALS is not triggered if automatic call after alarm is active. Howev-
er, if a call, for example an automatic call after alarm, is already established dur-
ing ALS, ALS will be silenced during this call.
NOTICE:
The handset can be configured to request to enter a password to turn
off the ALS.
A31003-M2000-U109-01-7619, 29/04/2020
44