AI/Event Management
SMT User Manual
80
value according to the practical conditions since the sensitivity is influenced by color and time
(day or night).
Duration
: it refers to the interval time between the adjacent motion detections. For instance, if
the duration time is set to 10 seconds, once the system detects a motion, it will go to alarm and
would not detect any other motion (specific to camera) in 10 seconds. If there is another motion
detected during this period, it will be considered as continuous movement; otherwise it will be
considered as a single motion.
③
Drag the camera image to set the motion area. You can set more than one motion area.
Click ―All‖ to set the whole camera image as the motion area. Click ―Reverse‖ to swap the
motion area and the non-motion area. Click ―Clear‖ to clear all the motion areas.
④
Click ―Apply‖ to save the settings. Click ―Processing Mode‖ to go to the alarm handling
configuration interface of the motion alarm.
12.4.2 Motion Alarm Handling Configuration
①
Click Start
Settings
AI/Event
Motion Alarm to go to the following interface.
②
Enable or disable ―Record‖, ―Snapshot‖, ―APP Push‖, ―Alarm-out‖, ―Buzzer‖, ―Pop-up
Video‖ and ―E-mail‖. The alarm handling setting of motion alarm is similar to that of the
sensor alarm (see 12.3 Sensor Alarm for details).
③
Click ―Apply‖ to save the settings. You can click ―Motion Settings‖ to go to the motion
configuration interface.
12.5 Combination Alarm
①
Click Start
Settings
AI/Event
Combination Alarm to go to the following interface.
②
Customize combination alarm. Set alarm name and click ―Configure‖ under the Combined
Alarm Configuration item. Then select alarm type and alarm source. Finally, click ―OK‖ to
save the settings.
③
Enable or disable ―Record‖, ―Snapshot‖, ―APP Push‖, ―Alarm-out‖, ―Buzzer‖, ―Pop-up
Video‖ and ―E-mail‖. The alarm handling setting of combination alarm is similar to that of the
sensor alarm (see 12.3 Sensor Alarm for details).
④
Click ―Apply‖ to save the settings.