Copyright © 2000 Tunstall Group Ltd.
Lifeline 4000 Advanced User Guide (B)
59
Entry/Exit time
Once a resident as set the intruder alarm he or she has a certain amount of time to leave before
the intruder monitoring becomes active. Lifeline also allows the same amount of time for a resident
to disable the intruder alarm upon their return. You can set this time to anywhere between 0 and
120 seconds using parameter 49. Note that you must always enter three digits for this parameter,
even if you set the time for just five seconds (i.e. 005 seconds).
Example
To set the intruder entry/exit time to 60 seconds
1.
Enter local programming mode by holding down the
key and then holding down the
# key until the unit beeps. Release the # key first, and then the
key.
2.
Enter the parameter—press
4 9
.
3.
Delete the old value using the C key (display version only).
4.
Enter 0 6 0 and then press
.
5.
End local programming by pressing the
Cancel
key.
Personal Identification Number (PIN)
In order to disable the intruder alarm the resident needs a personal identification number (PIN).
This must be a four-digit number. You can set this using parameter 50.
Example
To set the intruder PIN to 1234
1.
Enter local programming mode by holding down the
key and then holding down the
# key until the unit beeps. Release the # key first, and then the
key.
2.
Enter the parameter—press
5 0
.
3.
Delete the old value using the C key (display version only).
4.
Enter 1 2 3 4 and then press
.
5.
End local programming by pressing the
Cancel
key.
Summary of Contents for Lifeline 4000
Page 4: ...4 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Page 24: ...24 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Page 72: ...72 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Page 74: ...74 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Page 79: ...Copyright 2000 Tunstall Group Ltd Lifeline 4000 Advanced User Guide B 79...