Copyright © 2000 Tunstall Group Ltd.
Lifeline 4000 Advanced User Guide (B)
45
A clarification regarding trigger types
It might be useful to just run through a few of the
different trigger types. The
Integral Button
is the
large red alarm button on the top of the home unit.
The
Personal
trigger type refers to personal radio
triggers, such as GEM, Amie and Fall Detector.
Home
Care Management
is the type of trigger/action where
a service provider enters their timed or non-timed
service using the numbered keys under the flap on
the top of Lifeline 4000.
Home Care Management
Primer
is where a service provider presses a button
(usually a radio trigger), and then presses their own
radio trigger, which indicates the service they have
provided. The
Information
trigger type can be used
for a variety of purposes. However, the most
common is a periodic call.
e
p
y
T
r
e
t
e
m
a
r
a
P
n
o
t
t
u
b
l
a
r
g
e
t
n
I
4
3
1
l
a
n
o
s
r
e
P
3
5
1
d
r
o
C
l
l
u
P
8
4
1
l
i
a
F
s
n
i
a
M
8
2
1
d
e
r
o
t
s
e
R
s
n
i
a
M
5
3
1
e
k
o
m
S
7
4
1
A
e
r
u
t
a
r
e
p
m
e
T
0
5
1
B
e
r
u
t
a
r
e
p
m
e
T
1
5
1
y
t
i
v
i
t
c
A
2
5
1
r
e
d
u
r
t
n
I
9
4
1
t
i
x
e
/
y
r
t
n
E
t
n
e
m
e
v
o
M
4
5
1
t
i
x
e
/
y
r
t
n
E
-
n
o
N
t
n
e
m
e
v
o
M
5
5
1
t
n
e
m
e
g
a
n
a
M
e
r
a
C
e
m
o
H
6
3
1
r
e
m
i
r
P
t
n
e
m
e
g
a
n
a
M
e
r
a
C
e
m
o
H
6
5
1
n
o
i
t
a
m
r
o
f
n
I
9
3
1
y
a
l
e
D
m
r
a
l
a
e
r
P
l
l
a
C
n
o
i
t
a
c
i
d
n
I
r
e
g
g
i
r
T
s
e
s
U
l
l
a
C
e
c
n
e
u
q
e
S
l
a
n
r
e
t
x
E
t
u
p
t
u
O
n
O
e
m
i
T
f
f
O
e
m
i
T
0
0
0
0
2
0
0
0
The table on the next page shows the entries for Call Indication and Trigger Uses.
Examples
Set the action for the smoke call type
1.
Enter local programming mode by holding down the
key and then holding down the
# key until the unit beeps. Release the # key first.
2.
Enter the parameter—press
1 4 7
.
3.
Delete the old value using the C key.
4.
Enter 0 0 0 0 2 0 0 0 , and then press
.
5.
End local programming by pressing the
Cancel
key.
The actions for some trigger types are simple to set. A smoke detector needs no prealarm delay,
and so this is set to 00. We want the call progress visual signs and tones to be seen and heard and
so we set this to 0 (see table later). We do not want a smoke detector to answer a call, reset the
inactivity timer or set off the intruder alarm, and so we set this value to 0. We want calls of this
sort to used call sequence 2, and we do not want the smoke/fire detectors to switch the external
output.
Summary of Contents for Lifeline 4000
Page 4: ...4 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Page 24: ...24 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Page 72: ...72 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Page 74: ...74 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Page 79: ...Copyright 2000 Tunstall Group Ltd Lifeline 4000 Advanced User Guide B 79...