11 ROUTINE MAINTENANCE
ANY MAINTENANCE OPERATION MUST BE CARRIED OUT WITH THE ENGINE OFF AND COLD IN THE
CASE OF ENDOTHERMIC VERSION OF THE MACHINE (50&70 ST) AND WITH THE BATTERY
DISCONNECTED IN THE ELECTRIC VERSION (50&70 BT).
11.1 Cleaning the dust filter:
Check the dust filter
Detail 1 Fig. 8
every
40-70 working hours or as necessary. Open
the cover
Detail 1 Fig.1
to access the filter
compartment.
Cleaning the filter: with the bin
Detail A
Fig.1
in place, point the compressed air
gun towards the top of the filter so that the
dust falls into the bin. Make sure the filter is
in good condition and replace it if
necessary.
11.2 Dust seals:
Check the condition of the flaps every 40/70 hours. Damage or inefficiency of the flaps jeopardises the performance of
the machine in terms of cleaning quality,
Detail 4 Fig. 6
.
IMPORTANT: To replace the side flaps, make sure that their lower edge is 2-3 mm from the ground.
11.3 Side brush:
Detail 1 Fig. 9
. Keep raised from the ground when not in use to avoid raising dust unnecessarily. Keep raised from the
ground when the machine is not in use and make sure it does not come into contact with other objects which could bend
it making it unserviceable.
11.4 Centre brush:
To clean the centre brush.
The following implements are necessary for carrying out this operation:
heavy duty gloves, breathing mask, pliers, scissors
Check the condition of the central brush every 50/80 running hours, or
more frequently if the machine is used for particularly heavy duties. To
gain visual access to the central brush, remove the refuse container
(
Detail A Fig. 1
) and tip the machine as shown in
Fig. 9
, by pressing
down the handle.
If any ropes, wires or other refuse of this type has been inadvertently
collected up, wear the heavy duty gloves and the protective mask to
eliminate any refuse that has been wound in the brush.
FOR ELECTRIC MACHINES, REMOVE THE BATTERIES BEFORE TILTING SO AS TO AVOID SPILLAGE
OF THE SULPHURIC ACID SOLUTION.
Summary of Contents for 50&70 Series