GS/
VIPER
50DS
VarioStress
ANTI-JAM SYSTEM
An automat
(
3
)
controls
the No Stress anti-jam
system’s solenoid valve.
It is located with the
protection fuses
(
5
)
(1
amp.) and
(
4
)
(10 amp.)
in the distribution box
located on the hopper’s
right front part.
The primary circuit’s
protection fuse
(
6
)
(10 amp.) is in the watertight
fuse-holder on the starter cable.
D E S C R I P T I O N A N D
M A N I P U L A T I O N
The
distance
between the speed
controller
(
1
)
and
the pulse device
(
2
)
is
0,16 to 0,20 in (4
à
5 mm)
.
The VIPER is equipped with a controller of the rotation of the rotor that is linked to an
automat. Hence, we can prevent the machine from being blocked: permanent information
about the rotating speed of the rotor is being sent to the VarioStress. When the rotor speed
falls below a factory-set threshold, the hydraulic supply of the feed is interrupted. The feed
and belt will stop, the machine will no longer be fed material and the engine can reach its
working speed agian (2700T/mn). When the speed exceeds the lower threshold, the feed
roll and belt are supplied with oil again and the engine starts running again.
There are three anti-obstruction settings: see the next page