CS1000 - Revised 10/1/2012
DESCRIPTION
CS1000 is a concentrated aqueous blend of
organic corrosion inhibitors selected to
provide maximum protection for ferrous and
nonferrous metals.
APPLICATION
CS1000 is used in closed water systems
including chilled water, hot water, and diesel
engine jacket water systems. It is formulated to
rapidly establish and maintain a corrosion
inhibition film on clean metal surfaces. Rubber
and other nonmetallic materials are not adversely
affected by CS1000.
PHYSICAL PROPERTIES
Color & Form .......................... Light red liquid
Specific Gravity ..................................... 1.172
Density ......................................... 9.77 lbs/gal
pH ........................................................... 11.4
Odor ........................ Slightly pungent, organic
DOSAGE & FEEDING
INITIAL: Add one gallon (9.8 pounds) of
CS1000 for each 100 gallons of water in the
system to be treated.
CONTINUING: Subsequent additions of
CS1000 are governed by the "M" alkalinity of
the treated water and depend on the amount
of water leakage from the system. When the
"M" alkalinity of the treated water drops to
1,000 ppm in excess of the makeup water
"M" alkalinity, add one quart (2.5 pounds) of
CS1000 for each 100 gallons of water in the
system.
CLOSED LOOP
TREATMENT
CS1000
Add the required quantity of CS1000 to the
system using a by-pass feeder. This can be
installed at any convenient location in the
system.
Additional treatment will usually be needed
only once or twice per year.
NOTE: New installations should be free of
oil, grease, dirt, etc., prior to charging with
CS1000. CL83 is a proven cleaner
specifically formulated for this purpose.
HANDLING & PRECAUTIONS
CS1000 does not deteriorate with age. It is an
alkaline formulation and should be handled as
such. Avoid eye and skin contact. Flush affected
areas with large quantities of water. Obtain
medical attention for eyes.
Refer to
Material Safety Data Sheet
for
additional safe handling information.
PACKAGING
CS1000 liquid is available in:
5-gallon pails .............................. net wt 45 lbs
30-gallon pails ..........................net wt 290 lbs
55-gallon drums ........................net wt 550 lbs
Summary of Contents for AM4A0A18S11SA Series
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ......
Page 100: ...96 CLCH SVX07C EN Installation Electrical Figure 84 Typical VFD wiring schematic ...
Page 101: ...CLCH SVX07C EN 97 Installation Electrical Figure 85 Typical starter wiring schematic ...
Page 135: ...CLCH SVX07C EN 131 Notes ...
Page 146: ...10 1 2 STEP 8 Lift the Coil section up and away from the Blower section Set aside ...
Page 178: ......
Page 188: ...2 ...
Page 189: ...3 ...
Page 190: ...4 ...
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ......
Page 205: ......
Page 206: ......
Page 207: ......
Page 208: ......
Page 209: ......
Page 210: ......
Page 211: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......
Page 250: ......
Page 251: ......