B01087
E2
SST
VAF
Ohmmeter
--
ELECTRONIC FUEL INJECTION
VARIABLE RESISTOR
FI--57
(c)
Using SST, turn the idle mixture adjusting screw fully
counterclockwise .
(d)
Connect the ohmmeter to terminals VAF and E2 of the
variable resister, and turn the idle mixture adjusting screw
fully clockwise and check that the resistance value
changes from approx. 5 k
Ω
to 0
Ω
accordingly.
(e)
Reconnect the variable resistor connector.