ELECTRONIC FUEL INJECTION
VSV FOR EVAPORATIVE EMISSION (EVAP) (2RZ--FE,
3RZ--FE)
VSV FOR EVAPORATIVE
EMISSION (EVAP)
(2RZ -- FE,
3RZ -- FE)
INSPECTION
1.
REMOVE VSV
(a)
Disconnect the connector and 2 EVAP hoses from the
VSV.
(b)
Remove the 2 bolt and VSV assembly.
(c)
Remove the screw and VSV.
2.
INSPECT VSV
(a)
Using an ohmmeter, check that there is continuity be-
tween the terminals.
Resistance: At 20
˚
C (68
˚
F): 30 --34
Ω
If there is no continuity, replace the VSV.
(b)
Using an ohmmeter, check that there is no continuity be-
tween each terminal and the body.
If there is continuity, replace the VSV.
(c)
Inspect VSV operation
S
Check that air does not flow from ports E to F.
NOTICE:
Never apply more than 93 kPa (0.95 kgf/cm
2
, 13.5 psi) of
pressure compressed air to the VSV.
S
Apply battery positive voltage across the terminals.
S
Check that air flows from ports E to F.
If operation is not as specified, replace the VSV.
3.
REINSTALL VSV