A01600
CO079--01
CO1205
Part ”A”
Stopper Bolt
SST
Dimension ”B”
Overhaul Handle
Claw
A01601
Tank
Lock Plate
SST
Stopper Bolt
A01602
Tap
A01714
CO--14
--
COOLING
RADIATOR
DI SASSEMBLY
1 . RE MO V E RADI ATO R S UP P O RTS
(a)
Remove the 4 bolts and 2 radiator supports.
2 . RE MO V E DRAI N P LUG
3.
ASSEMBL E SST
SST 09230 -- 01010
(a)
Install the claw to the overhaul handle, inserting it in the
hole in part ”A” as shown in the diagram.
(b)
While gripping the handle, adjust the stopper bolt so that
dimension ”B” shown in the diagram is 0.2 -- 0.3 mm
(0.008 -- 0.012 in.).
NOTICE:
If this adjustment is not done, the claw may be damaged.
4 . UNCAULK L O CK P LATE S
Using SST to release the caulking, squeeze the handle until
stopped by the stopper bolt.
SST 09230 -- 01010
5 . RE MO V E TANKS AND O -- RI NG S
(a)
Lightly tap the radiator port (inlet or outlet) with a soft--
faced hammer, and remove the tank.
(b)
Remove the O--ring.
6. 1RZ -- E:
RE MOVE OIL COOLER FROM LOWE R TANK
(a)
Remove the pipes.
HINT:
Make a note of the direction to face the pipes.
(b)
Remove the nuts and plate washers.
(c)
Remove the oil cooler and O--rings.
CLICK HERE TO VIEW CHAPTER INDEX
Pages From Supplement