A-28
broadcast writes the current group to x.1.8. Only devices assigned to the current group respond
to their slave address.
15.
Communications Schedule is used to conserve power during times of inactivity.
16.
Not all protocols maintain communications statistics.
17.
Some protocols scan a directory for request blocks or register maps. If you wish to share a
register map across ports, change the protocol directory to point to a common directory.
18.
By assigning this register to a digital output, an oscilloscope can be used to measure protocol
request/response timing. When using multiple XMVs on a common bus, this can be used to
verify each device is reliably being scanned once a second (API 21.1 compliance).
19.
All FLASH images do not contain all protocols. Register x.5.0 contains the number of protocols
in the FLASH image. Registers x.5.1 through x.5.(x.5.0) contains the protocol type codes each
protocol in the FLASH image. Registers x.6.1 through x.6.(x.5.0) contain the text descriptions for
each protocol in the FLASH image.
FS2 Application Registers (Rev AA)
FS2 Byte Registers
REGISTER DESCRIPTION
Type
0.0
Fs2 Dump Database(DB2 Collect)
Read-number of days = all/Write
select number of days
0.1
FS2 Locate and lock selected Display
Write
0.2
Trend Append to DB2 Collect
Read/Write
0.3 Contract
Day
Read/Write
0.4
Incremental Features Flags(set to 0xFF for Xseries)
Read/Write – see note 1
0.5 Feature
Flags
Read/Write
0.6
Lock Calcs(Dummy return value =1,
For”LC” command.
Read Only
0.7
Remote Protocol Selection(Totalflow Remote = 2, Modbus
Ascii=3)
Read/Write
0.8
Remote Protocol Stop bits selection(1 stop bit = 1, 2 Stop
bits =3)
Read/Write
0.9
Remote Protocol Interface selection(Modem = 64,
RS485=1, RS232=0, RS422=2)
Read/Write
0.10
Display Time for selected display item
Read/Write
0.11
Calc cp_test(
aga7Test701)
Write
FS2 Byte Register Usage Notes:
Note 1:
1.
FS2 Feature Flag Bits:
0x02, 2 /* Pulse Input */
0x10, 16 /* Valve Support */
0x20, 32 /* BC Ext Char */
0x40, 64 /* API AGA85 Calc */
0x80, 128 /* External Features */
Summary of Contents for XRC6490
Page 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Page 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Page 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Page 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Page 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Page 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...