A-126
0x20, 20
/* Use Live Analyzer Data in volume calc */
0x40, 40
/* Use Fixed Ax data on analyzer error *
/
0x80, 80
/
* reserved */
14.
This is for internal use only. A logic 1 disables tube cold and warm start functions.
15.
When this flag is 1 no events are allowed and no parameter changes are allowed from any
protocol.
16.
When this flag is 1 no events are allowed and no parameter changes are allowed.
17.
When this bit is logic 1 and the transducer is a gage transducer pressure logging in Log and Day
records is done Gage Pressure. The log gage pressure is computed by subtracting the
barometric pressure from the average of the input pressure over the log/day period.
18.
With pressure applied to SP.
19.
Used only with Selectable Units.
20.
Gas orifice only.
Tube 16-bit Integer Registers
ARRAY.REGISTER DESCRIPTION
USAGE
GROUP
NAME
1.0
Primary Element Mask
Read Only, indicates primary
element type, see note 1)
None
1.1
Calc Method Mask
Read Only, indicates calculation
methods supported, see note 2)
None
1.2
Calc Units Mask
Read Only, not used
None
1.3
Report Units Mask
Read Only, not used
None
1.4
Super Comp Method
Mask
Read Only, indicates super-
compressibility methods that may
be selected. See note 3)
None
1.5
Live Analysis Update
Interval
Read/Write, live analysis updates
are expected in this interval,
expressed in seconds
None
1.6
Volume Calc period
Read/Write, seconds
None
1.7
Daily Record Capacity
Read/Write, number of daily
records, change to this value
deletes existing database and
starts new database
None
1.8
Log Record Capacity
Read/Write, number of log period
records, change to this value
deletes existing database and
starts new database
None
1.9
Event Record Capacity
Read/Write, number of event
records, change to this value
deletes existing database and
starts new database
None
1.10
Aux Contact 1 Select Bits
Read/Write, control bits, see note
4)
None
1.11
Aux Contact 2 Select Bits
Read/Write, control bits, see note
4)
None
1.12
Return number of events
available
Write, Canadian Event Log
None
1.13
Therms Stream Id
Read/Write Analysis Stream Id
None
Summary of Contents for XRC6490
Page 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Page 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Page 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Page 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Page 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Page 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...