A-127
ARRAY.REGISTER DESCRIPTION
USAGE
GROUP
NAME
1.14
Modbus address of
analyzer
Read/Write None
1.15
Therms use fixed or last
good
Read/Write None
1.16
Daily Record Sequence
Number
Read Only
None
1.17
Log Record Sequence
Number
Read Only
None
1.18
Event Record Sequence
Number
Read Only
None
1.19
DP Status Flags
Read Only, see note 5)
None
1.20
AP Status Flags
Read Only, see note 6)
None
1.21
TF Status Flags
Read Only, see note 7)
None
1.22
PI Status Flags
Read Only, see note 8)
None
1.23
Ext Status Flags
Read Only, see note 9)
None
Tube 16-bit Integer Register Usage Notes:
1.
Primary Element Mask: 1=Orifice Square Root
2.
Calculation Method Mask: 2=AGA-3 1985, 4=AGA-3 1992; The sum of these values (6)
indicates 2 and 4 are valid choices.
3.
Super-Compressibility Method Mask: 1=NX19 with FIXED FT AND FP VALUES, 2=NX19 AUTO,
4=NX19 GRAVITY CO2 & N2, 8=NX19 CO2 & N2 & C1, 2048=AGA8 Gross, 4096=AGA8
Detail. The sum of these values (6159) indicates all of the choices listed above are valid.
4.
Aux Contact Select Bits: 1=trip contact on low charger; 2=trip contact on Dp low; 4=trip contact
on Dp high; 8=trip contact on Ap low; 16=trip contact on Ap high; 32=trip contact on Remote
Sense; 64=auto re-open; 128=trip contact on volume set-point; 256=trip contact on tf low;
512=trip contact on tf high; 1024=trip contact on flow rate low; 2048=trip contact on flow rate
high; 16384=reverse contact logic.
5.
Dp Status Flags: 1=low limit exceeded; 2=high limit exceeded; 4=over-range; 8=zero flow;
16=back flow.
6.
Ap Status Flags: 1=low limit exceeded; 2=high limit exceeded; 4=over-range; 8=zero flow;
32768=gauge pressure device.
7.
Tf Status Flags: 1=low limit exceeded; 2=high limit exceeded; 4=over-range.
8.
PI Status Flags: 1=low limit exceeded; 2=high limit exceeded; 8=zero flow.
9.
Ext Status Flags: 1=low limit exceeded; 2=high limit exceeded; 8=zero flow.
Tube 32-bit Integer Registers
ARRAY.REGISTER DESCRIPTION
USAGE Group
Name
2.0
Log period
Read/Write, seconds
None
2.1
Julian timestamp of most recent
AIU download
Read/Write, see note 1)
Date/Time
2.2
Julian timestamp of most recent
live component update (not aiu)
Read/Write, see note 1)
Date/Time
Summary of Contents for XRC6490
Page 1: ...2100802 001 AB TOTALFLOW XSeries Remote Controller User s Manual ...
Page 6: ...iv B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 10: ...viii B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 19: ...1 5 Standard Enclosure Cont RC 6790 X Figure 1 2 Model XRC6790 Continued on Next Page ...
Page 41: ...1 27 Totalflow Input Output Modules Cont Figure 1 16 XRC6990 Inside View ...
Page 42: ...1 28 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 64: ...2 22 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 86: ...4 12 Replacing XRC 195 Board Cont Figure 4 5 XRC Board Connections ...
Page 88: ...4 14 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 112: ...5 24 12V Communication Supply Voltage Test Cont Figure 5 9 XRC 195 Communication Wiring ...
Page 292: ...A 176 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 340: ...B 48 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...
Page 342: ...C 2 B B Bl lla a an n nk k k P P Pa a ag g ge e e ...