730CDT
2-29
Figure 2-3 Display connection
If any of the cables are not connected, reconnect it firmly and repeat Procedures 1 and 2. If
the problem still exists, perform Procedure 4.
Procedure 4
Replacement Check
The FL, FL inverter board, LCD module, and system board are connected to the display
circuits. Any of these components may be damaged. Refer to
Chapter 4
,
Replacement
Procedures
, for instructions on how to disassemble the computer and then perform the
following checks:
❑
If the FL does not light, perform Check 1.
❑
If characters are not displayed clearly, perform Check 3.
❑
If some screen functions do not operate properly, perform Check 3.
❑
If the FL remains lit when the display is closed, perform Check 4.
Check 1
Replace the FL with a new one and test the display again. If the problem still
exists, perform Check 2.
Check 2
Replace the FL inverter board with a new one and test the display again. If the
problem still exists, perform Check 3.
Check 3
Replace the LCD module with a new one and test the display again. If the
problem still exists, perform Check 4.