4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
EO18-33012B
(Revision Date: Jan. 19, 2007)
4.11 RFID MODULE (B-9704-RFID-H1-QM)
4-67
4.11.6 Parameter Setting and Operation Check for the RFID Module
After installing the RFID Module in the printer, set the parameters for the RFID and perform an
operation check by using the following procedures. For details, please refer to the Maintenance
Manual.
1) Start the printer in the System Mode, and check the program version. When the program version
is V3.1 or older, go to Step 2). When the program version is V4.1 or greater, go to Step 3).
2) When the program version is V3.1 or older, upgrade it to V4.1 or greater in the following order.
Please obtain the latest firmware from
http://barcode.toshibatec.co.jp/Ris/products/barcode/support/en/contents/software/index.html
(1) Print the Maintenance Counter/Parameter Setting to keep the record of the printer’s
parameter settings. (Refer to Section 5.3.)
(2) Download the firmware from the above web site, and upgrade the firmware version of the
printer. (Refer to Section 7.)
(3) Perform a Parameter Clear. (Refer to Section 5.8.)
(4) Return the all parameter settings except for RFID Module to the former ones.
3) Change the parameter setting of the RFID Module from ”NONE” to ”H1”. Choosing ”NONE”
or ”U1” results in NG (No good) at the self diagnostic test even if the RFID Module is properly
connected.
4) Change the parameter setting of the RFID tag type to a proper one.
5) Print the Maintenance Counter/Parameter Settings and the Self-Diagnostic Test result to confirm
the RFID Module status.
5) If “RFID NG” (No Good) is printed, check the cable connections and parameter settings related to
the RFID Module again.
6) Try a read and write of the RFID tag by using the RFID Analyze Tool. When you do not have a
PC at hand, perform a simplified read test in the system mode to confirm the data can be read.
In case that the read/write accuracy needs to be enhanced, make an adjustment of the parameter
setting in the System Mode. (Refer to Section 11 and Section 5.2.)
NOTE: Available RFID tags
TAGSYS (C210, C220, C240, C320) *C320 is available only when the TAGSYS S003 module is used.)
I-Code
Tag-It
ISO
15693
Maintenance Counter/Parameter Settings Label (Example)
Make sure that [H1] is selected and other parameters for the RFID
Module are printed as follows.
WEP KEY #3
[101112131415161718191A1B1C]
WEP KEY #4
[202122232425262728292A2B2C]
RFID MODULE
[H1]
RFID TAG TYPE
[ISO15693
]
RFID ERR CHECK
[OFF]
RFID RETRY
[ 3]
RFID RD CYCLE
[ 5]
[4.0sec.]
RFID WT CYCLE
[ 5]
[2.0sec.]
RFID ADJ RETRY
[+00mm]
RFID POWER LEV
[251]
Parameters for the
RFID Module
Initial values
Self-Diagnostic Test Label (Example)
Make sure that “
RFID
OK”
is printed.
SENSOR2 [H]
23ºC
[A]22ºC
[R]4.2V
[T]2.5V
[E]0.6V
[RANK]7
EXP. I/O
NG
EX. 232C
NG
RFID OK
V
****
Self-diagnosis of the
RFID Module status
Version No.