4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
EO18-33012B
(Revision Date Apr. 24, 2008)
4.22 RFID MODULE (B-SX704-RFID-U2-EU-R)
4-137
19. Close the Ribbon Shaft Holder Plate, and tighten the two screws, which were temporarily tightened in
Step 18, while holding down the Print Head Block.
20. Open the Ribbon Shaft Holder Plate again, and tighten the SMX-2.6x6 screw to secure the Head Side
Plate.
Print Head Block
Double Sems Screw
SMW-4x8
Double Sems Screw
SMW-3x6
Ribbon Shaft
Holder Plate
Head Lever
Double Sems Screw
SMW-2.6x6
Head Side Plate