4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
EO18-33012B
(Revision Date May 29, 2008)
4.23 RFID MODULE (B-SX704-RFID-U2-AU-R)
4-175
<10>RFID
TAG NONE
RFID tag type setting menu is displayed.
Choose “EPC C1 Gen2: 24” with the
[FEED]
or
[RESTART]
key.
[RESTART]
[FEED]
NONE: When a tag type is not selected.
EPC C1 Gen2: 24
[PAUSE]
Press the
[PAUSE]
key.
<10>RFID
ERR CHK OFF
RFID error tag detection menu is displayed. Choose whether to perform an error tag
detection or not with the
[FEED]
or
[RESTART]
key.
[RESTART]
[FEED]
OFF
: An error tag detection is not performed. (Usually,
choose OFF.)
ON: An error tag detection is performed.
ON:
A tag is read before writing data on it, and data is written on the tag only when the
header data is “A5A5”.
OFF: Though a tag is read before writing data on it, data write is always performed
whatever data has been set as the header data.
[PAUSE]
Press the
[PAUSE]
key.
Continued to the next page.
Continued from the previous page.
<10>RFID
ISSUE RETRY 3
Max. number of issue retries setting menu is displayed.
Set a maximum number of retries to issue an RFID tag.
When issuing an RFID tag failed, the printer prints the error pattern, and retries to issue the
tag for up to specified number of times. If the printer does not succeed even after having
retried for the max. times, the printer stops, resulting in an error.
Choose the max. number of retries with the
[FEED]
or
[RESTART]
key.
[PAUSE]
[RESTART]
[FEED]
255
•
•
•
3 (Default)
•
•
0
Press the
[PAUSE]
key.
<10>RFID
R CYCLE CNT 5
Max. number of read retries setting menu is displayed.
Set a maximum number of retries to read an RFID tag.
The printer retries to read the data in an RFID tag for up to specified number of times. If the
timeout period expired before the max. number retries have been done, the printer stops the
retries at the time.
Whenever the printer writes data onto an RFID tag, the tag is read first. The max. number of
retries set by this parameter becomes also effective in this pre-read.
Choose the max. number of retries with the
[FEED]
or
[RESTART]
key.
[RESTART]
[FEED]
255
•
•
•
5 (Default)
•
•
0
Press the
[PAUSE]
key.
[PAUSE]