![Toshiba TEC B-SX4T Series Maintenance Manual Download Page 72](http://html.mh-extra.com/html/toshiba/tec-b-sx4t-series/tec-b-sx4t-series_maintenance-manual_424381072.webp)
4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
EO18-33012B
(Revision Date: Feb. 15, 2007)
4.10 RFID MODULE (B-9704-RFID-U1-US/EU/EU-R)
4-55
4) Print the Maintenance Counter/Parameter Settings and the Self-Diagnostic Test result to confirm
the RFID Module status.
5) If “RFID NG” (No Good) is printed, check the cable connections and parameter settings related to
the RFID Module again.
6) Try a read and write of the RFID tag by using the RFID Analyze Tool. When you do not have a
PC at hand, perform a simplified read test in the system mode to confirm the data can be read.
In case that the read/write accuracy needs to be enhanced, make an adjustment of the parameter
setting in the System Mode. (Refer to Section 11 and Section 5.12.)
NOTE:
Available RFID tags
EPC Class 0 (Read only)
EPC Class 1
EPC Class 1 Gen2 (Only when the RFID module supports Gen2)
ISO
18000-6B
WEP KEY #3
[101112131415161718191A1B1C]
WEP KEY #4
[202122232425262728292A2B2C]
RFID MODULE
[U1]
RFID TAG TYPE
[EPC CI Gen2
]
RFID ERR CHECK
[OFF]
RFID RETRY
[ 3]
RFID RD CYCLE
[ 5]
[4.0sec.]
RFID WT CYCLE
[ 5]
[2.0sec.]
RFID ADJ RETRY
[+00mm]
RFID POWER LEV
[50]
Parameters for
the RFID Module
Initial values
Example: Maintenance Counter/Parameter Settings Label
Make sure that [U1] is selected and other parameters for the
RFID Module are printed as follows.
Example: Self-Diagnostic Test Label
Make sure that “
RFID
OK”
is printed.
SENSOR2 [H]
23ºC
[A]22ºC
[R]4.2V
[T]2.5V
[E]0.6V
[RANK]7
EXP. I/O
NG
EX. 232C
NG
RFID OK
V
****
Self-diagnosis of the
RFID Module status
Version No.
US/EU mode: 251
EU-R model: 50