3 Tests and Diagnostics
3.8 Floppy Disk Test
Subtest 01
Sequential read
This subtest performs a Cyclic Redundancy Check (CRC) that continuously
reads all the tracks (track: 0 to 39/0 to 79) on a floppy disk.
The start track is specified at the start of the FDD test. Refer to 2 in this
chapter.
Subtest 02
Sequential read/write
This subtest continuously writes data pattern B5ADADh to all the tracks
(track: 0 to 39/0 to 79) on a floppy disk. The data is then read and compared
to the original data.
Subtest 03
Random address/data
This subtest writes random data to random addresses on all tracks (track: 0 to
39/0 to 79) on a floppy disk. The data is then read and compared to the
original data.
Subtest 04
Write specified address
This subtest writes the data specified by an operator to a place pointed by
track, head, and address.
Subtest 05
Read specified address
This subtest reads data from a place pointed by track, head, and address
specified by an operator.
3-22
Satellite A10/TECRA A1/Satellite Pro A10 Maintenance Manual (960-445)