4. Outdoor fan control
Allocations of fan tap revolutions [rpm]
1) Cooling fan control
The outdoor fan is controlled by TE, TD, and TO sensors and also revolution frequency of the operation.
The outdoor is controlled by every 1 tap of DC fan control (15 taps).
Only during 60 seconds after the operation has started, the fan is fixed with the maximum fan tap
which corresponds to the zone in the following table.
After then the fan is controlled by TE sensor temperature.
Considering a case that TE sensor has come out of the holder, the fan is controlled so that revolution
frequency of the fan increases regardless of TE if temperature of TD sensor has risen.
SP40, SP45
W1
W2
W3
W4
W5
W6
W7
W8
W9
WA
WB
WC
WD
WE
WF
200
300
350
410
480
500
560
640
670
700
750
800
800
840
840
Temp. range
38°C
≤
TO
32
≤
TO < 38°C
15
≤
TO < 32°C
5
≤
TO < 15°C
1
≤
TO < 5°C
–5
≤
TO < 1°C
TO < –5°C
TO error
f < 34.1Hz
34.1Hz
≤≤≤≤≤
f < 58.6Hz
58.6Hz
≤≤≤≤≤
f
Min.
Max.
Min.
Max.
Min.
Max.
W6
WB
W8
WD
WA
WF
W5
WA
W7
WC
W9
WF
W3
W7
W5
W9
W7
WB
W2
W5
W4
W7
W6
W9
W1
W3
W3
W5
W4
W7
W1
W2
W2
W4
W3
W5
OFF
OFF
W3
W1
W4
W1
WF
W1
WF
W1
WF