– 17 –
1-2. Outdoor Unit
<Super Digital Inverter>
Model name
Outdoor unit
RAV-SP
Power supply
Type
Compressor
Motor
(kW)
Pole
Refrigerant charged
(kg)
Refrigerant control
Standard length
(m)
Min. length
(m)
Inter
Max. total length
(m)
connecting
Additional refrigerant charge
pipe
under long piping connector
Height
Outdoor lower
(m)
difference
Outdoor higher
(m)
Outer
Height
(mm)
Width
(mm)
dimension
Depth
(mm)
Appearance
Total weight
(kg)
Heat exchanger
Fan
Fan unit
Standard air flow
(m³/min.)
Motor
(W)
Connecting
Gas side
(mm)
pipe
Liquid side
(mm)
Sound pressure level
Cooling/Heating
(dB•A)
Sound power level
Cooling/Heating
(dB•A)
Outside air temperature, Cooling
(°C)
Outside air temperature, Heating
(°C)
404AT(Z)(ZG)-E
454AT(Z)(ZG)-E
564AT(Z)(ZG)-E
804AT(Z)(ZG)-E
1 phase 230V (220 – 240V) 50Hz
(Power exclusive to outdoor is required.)
Hermetic compressor
1.1
1.1
1.1
2.0
4
4
4
4
1.0
1.0
1.4
2.1
Pulse motor valve
7.5
7.5
7.5
7.5
5
5
5
5
30
30
50
50
20g/m
20g/m
20g/m
40g/m
(21m to 30m)
(21m to 30m)
(21m to 50m)
(31m to 50m)
30
30
30
30
30
30
30
30
550
550
550
890
780
780
780
900
290
290
290
320
Silky shade (Muncel 1Y 8.5/0.5)
40
40
44
63
Finned tube
Propeller fan
40
40
40
50
43
43
43
63
12.7
12.7
12.7
15.9
6.4
6.4
6.4
9.5
45 / 47
45 / 47
47 / 48
48 / 49
62 / 64
62 / 64
63 / 64
64 / 65
43 to – 15°C
15 to – 15°C
15 to – 20°C