– 16 –
<Twin type>
Indoor unit 1
RAV-SM404SDT-E
Model
Indoor unit 2
RAV-SM404SDT-E
Outdoor unit
RAV-SP804AT(Z)(ZG)-E
Cooling capacity
(kW)
7.1
Heating capacity
(kW)
8.0
Indoor unit
Power supply
1 phase 230V (220 – 240V) 50Hz
Running current
(A)
10.36 – 9.49
Power consumption
(kW)
2.21
Cooling
Power factor
(%)
97
EER
3.21
Electrical
Energy efficiency class
∗
A
characteristics
Running current
(A)
10.12 – 9.28
Power consumption
(kW)
2.16
Heating
Power factor
(%)
97
COP
3.70
Energy efficiency class
∗
A
Fan
Centrifugal
Fan unit
Standard air flow
H/M/L
(m³/min.)
11.5 / 10.0 / 8.7
Motor
(W)
60
Sound
Under air inlet
H/M/L
(dB•A)
39 / 36 / 33
pressure level
Back air inlet
H/M/L
(dB•A)
30 / 28 / 26
Sound
Under air inlet
H/M/L
(dB•A)
54 / 51 / 48
power level
Back air inlet
H/M/L
(dB•A)
45 / 43 / 41
Outdoor unit
Power supply
1 phase 230V (220 – 240V) 50Hz
Standard length
(m)
7.5
Min. length
(m)
5
Refrigerant
Max. total length
(m)
50
Refrigerant charging amount
40g/m
pipe
(Charge-less up to 30m)
(31m to 50m)
Height
Outdoor lower
(m)
30
difference
Outdoor higher
(m)
30
Fan
Propeller fan
Fan unit
Standard air flow volume
(m³/min.)
50
Motor
(W)
63
Gas side
Main
(mm)
15.9
Connecting
Sub
(mm)
12.7
pipe
Liquid side
Main
(mm)
9.5
Sub
(mm)
6.4
Sound pressure level
Cooling/Heating
(dB•A)
48 / 49
Sound power level
Cooling/Heating
(dB•A)
64 / 65
∗
: IEC standard