– 9 –
<Cooling> RAS-M18GAV-E , RAS-M18GACV-E
<Heating>RAS-M18GAV-E
The above specification values are those under the conditions.
Cooling Indoor : DB/WB=27/19°C
Heating Indoor : DB=20°C
Outdoor : DB=35°C
Outdoor : DB/WB=7/6°C
Operation
mode
Cooling
Volts
V
220
230
240
Operation
status
1 unit
2 units
1 unit
2 units
1 unit
2 units
Operating
indoor unit
A
B
10
—
13
—
16
—
10
10
13
10
13
13
16
10
10
—
13
—
16
—
10
10
13
10
13
13
16
10
10
—
13
—
16
—
10
10
13
10
13
13
16
10
Unit capacity
(kW)
A
B
2.7
—
3.7
—
4.5
—
2.55
2.55
2.85
2.35
2.60
2.60
3.25
1.95
2.7
—
3.7
—
4.5
—
2.55
2.55
2.85
2.35
2.60
2.60
3.25
1.95
2.7
—
3.7
—
4.5
—
2.55
2.55
2.85
2.35
2.60
2.60
3.25
1.95
Capacity
kW
2.7 (1.1 to 3.2)
3.7 (1.1 to 4.2)
4.5 (1.1 to 4.9)
5.1 (1.4 to 6.1)
5.2 (1.4 to 6.2)
5.2 (1.4 to 6.2)
5.2 (1.4 to 6.2)
2.7 (1.1 to 3.2)
3.7 (1.1 to 4.2)
4.5 (1.1 to 4.9)
5.1 (1.4 to 6.1)
5.2 (1.4 to 6.2)
5.2 (1.4 to 6.2)
5.2 (1.4 to 6.2)
2.7 (1.1 to 3.2)
3.7 (1.1 to 4.2)
4.5 (1.1 to 4.9)
5.1 (1.4 to 6.1)
5.2 (1.4 to 6.2)
5.2 (1.4 to 6.2)
5.2 (1.4 to 6.2)
Running current
A
3.03 (1.43 to 03.83)
5.10 (1.43 to 06.49)
6.96 (1.43 to 07.88)
7.19 (1.69 to 09.97)
7.42 (1.69 to 10.06)
7.42 (1.69 to 10.06)
7.42 (1.69 to 10.06)
2.90 (1.37 to 03.66)
4.88 (1.37 to 06.21)
6.65 (1.37 to 07.54)
6.88 (1.61 to 09.54)
7.10 (1.61 to 09.63)
7.10 (1.61 to 09.63)
7.10 (1.61 to 09.63)
2.78 (1.31 to 03.51)
4.68 (1.31 to 05.95)
6.38 (1.31 to 07.23)
6.59 (1.55 to 09.14)
6.80 (1.55 to 09.23)
6.80 (1.55 to 09.23)
6.80 (1.55 to 09.23)
Power
Consumption
W
600 (220 to 800)
1100 (220 to 1400)
1500 (220 to 1700)
1550 (260 to 2150)
1600 (260 to 2170)
1600 (260 to 2170)
1600 (260 to 2170)
600 (220 to 800)
1100 (220 to 1400)
1500 (220 to 1700)
1550 (260 to 2150)
1600 (260 to 2170)
1600 (260 to 2170)
1600 (260 to 2170)
600 (220 to 800)
1100 (220 to 1400)
1500 (220 to 1700)
1550 (260 to 2150)
1600 (260 to 2170)
1600 (260 to 2170)
1600 (260 to 2170)
Operation
mode
Heating
Volts
V
220
230
240
Operation
status
1 unit
2 units
1 unit
2 units
1 unit
2 units
Operating
indoor unit
A
B
10
—
13
—
16
—
10
10
13
10
13
13
16
10
10
—
13
—
16
—
10
10
13
10
13
13
16
10
10
—
13
—
16
—
10
10
13
10
13
13
16
10
Unit capacity
(kW)
A
B
4.0
—
5.0
—
5.5
—
3.25
3.25
3.51
3.19
3.35
3.35
3.88
2.82
4.0
—
5.0
—
5.5
—
3.25
3.25
3.51
3.19
3.35
3.35
3.88
2.82
4.0
—
5.0
—
5.5
—
3.25
3.25
3.51
3.19
3.35
3.35
3.88
2.82
Capacity
kW
4.0 (0.7 to 5.2)
5.0 (0.7 to 6.5)
5.5 (0.7 to 6.9)
6.5 (0.9 to 8.2)
6.7 (0.9 to 8.5)
6.7 (0.9 to 8.5)
6.7 (0.9 to 8.5)
4.0 (0.7 to 5.2)
5.0 (0.7 to 6.5)
5.5 (0.7 to 6.9)
6.5 (0.9 to 8.2)
6.7 (0.9 to 8.5)
6.7 (0.9 to 8.5)
6.7 (0.9 to 8.5)
4.0 (0.7 to 5.2)
5.0 (0.7 to 6.5)
5.5 (0.7 to 6.9)
6.5 (0.9 to 8.2)
6.7 (0.9 to 8.5)
6.7 (0.9 to 8.5)
6.7 (0.9 to 8.5)
Running current
A
5.57 (1.10 to 7.88)
8.35 (1.10 to 11.73)
8.81 (1.10 to 11.73)
8.35 (1.30 to 11.09)
8.58 (1.30 to 11.36)
8.58 (1.30 to 11.36)
8.58 (1.30 to 11.36)
5.32 (1.06 to 7.54)
7.99 (1.06 to 11.22)
8.43 (1.06 to 11.22)
7.99 (1.24 to 10.60)
8.21 (1.24 to 10.87)
8.21 (1.24 to 10.87)
8.21 (1.24 to 10.87)
5.10 (1.01 to 7.23)
7.65 (1.01 to 10.76)
8.08 (1.01 to 10.76)
7.65 (1.19 to 10.16)
7.87 (1.19 to 10.42)
7.87 (1.19 to 10.42)
7.87 (1.19 to 10.42)
Power
Consumption
W
1200 (170 to 1700)
1800 (170 to 2530)
1900 (170 to 2530)
1800 (200 to 2390)
1850 (200 to 2450)
1850 (200 to 2450)
1850 (200 to 2450)
1200 (170 to 1700)
1800 (170 to 2530)
1900 (170 to 2530)
1800 (200 to 2390)
1850 (200 to 2450)
1850 (200 to 2450)
1850 (200 to 2450)
1200 (170 to 1700)
1800 (170 to 2530)
1900 (170 to 2530)
1800 (200 to 2390)
1850 (200 to 2450)
1850 (200 to 2450)
1850 (200 to 2450)