Appendix
Appendix-4
Upper cabinet
Valve cover
Wiring cover
Water-proof
cover
Front cabinet
Side cabinet (L)
Side cabinet (R)
Inverter assembly
4. Cord heater installation work procedure
No.
1
1-1
1-2
1-3
1-4
Photo / Explanatory diagram
Remove each cabinet, inverter assembly, motor base assembly, and partition board assembly.
∗
Do not damage the electric parts such as cables, connectors, etc. while this work
Procedure
Remove the upper cabinet and the valve cover.
Related parts / Screws list
Part name
Upper cabinet
Valve cover
Used screw
Screw type
Quantity
Ø4 × 8
5
Ø4 × 1
1
Remove the front cabinet, the wiring cover and the
water-proof cover.
Related parts / Screws list
Part name
Front cabinet
Wiring cover
Used screw
Screw type
Quantity
Ø4 × 8
7
Ø4 × 8
2
Remove the side cabinet (R/L) and the inverter assembly.
Related parts / Screws list
Part name
Side cabinet (R)
Side cabinet (L)
Inverter assembly
Used screw
Screw type
Quantity
Ø4 × 8
7
Ø4 × 8
3
Ø4 × 8
1
Remove the inverter assembly.
No.
1
2
3
4
5
6
7
8
9
Part name
TE sensor
TD sensor
TO sensor
TS sensor
4-way valve coil
PMV coil
Fan motor
Compressor
lead
Reactor
(2 pieces.)
Connector No.
CN600
CN601
CN602
CN603
CN701
CN700
CN300
(Intermediate
connector)
(Intermediate
connector)
Connector color
White
White
White
White
Yellow
White
White
White
White