– 53 –
Both indoor units
start operation.
Unnecessary set
[Remote controller select]
Press the operation button
on the remote controller.
YES
NO
CLOCK
CHECK
RESET
CLR
SET
SWING
FIX
FAN
ON
OFF
HiPOWER
ECO
MEMO
SLEEP
1.3.5.9H
When switching between
settings “A” and “B”, always
switch the indoor unit board and
the remote controller as a pair.
(Otherwise, the indoor unit will
not accept the remote
controller’s signals.)
Cutting direction
Jumper wire
Position of remote controller selector switch
Selector switch
Select “B” as the setting for
one of the two indoor units and
for the remote controller.
(See below for details.)
Item
17. Select switch on
remote controller
Operation flow and applicable data, etc.
Description
1. Purpose
This operation is to operate only one
indoor unit using one remote controller.
2. Description
When operating one indoor unit in a
situation where two indoor units have
been installed in the same room or
nearby rooms, this operation prevents the
remote controller signal from being
received simultaneously by both units,
thus preventing both units from operating.
3. Operation
The indoor unit on which the remote
controller selection has been set to B
receives the signal of the remote control-
ler also set to B.
(At the factory the remote controller
selection is set to A on all the indoor
units. There is no A setting display.)
Setting the remote controller
Switching between A and B is enabled by cutting the jumper wire
inside the battery box using pliers.
1) Slide open the remote controller cover and remove the
batteries.
2) Cut the jumper wire inside the battery compartment using
nippers.
• The jumper wire should not remain in contact after being cut.
Also, be careful not to let plastic scraps, jumper wire cuttings
or other debris enter the inside of the remote controller.
3) Insert the batteries. “B” appears in the remote controller
display.
∗
Even after the jumper wire has been cut, switching between
A and B is still possible by pressing the CHECK button and
FIX button together.
The A or B setting, which was switched by pressing the
CHECK button and FIX button together, is restored to the
setting established prior to the switching when the battery is
replaced or the RESET button is pressed.
Setting the selector switch on the main unit
• Remove the front panel, and then set the selector switch to “B”.
• After making the switch setting, remount the front panel.