– 141 –
9. OWNER’S MANUAL
Engineering Data book
4
USER MAINTENANCE
Periodic maintenance (once a year) is necessary for this product. Consult the installation company.
If a problem occurs, contact the installation company or dealer.
5
AIR TO WATER HEAT PUMP OPERATIONS
AND PERFORMANCE
3 minutes protection function
3-minutes protection function prevents the air to water heat pump from starting for initial 3 minutes after the main
power switch/circuit breaker is turned on for re-starting the air to water heat pump.
Power failure
Power failure during operation will stop the unit completely.
• To restart the operation, push the ZONE1, 2/HOT WATER button on the remote controller.
Heating characteristics
Defrosting operation
If the outdoor unit is frosted during the heating or hot water supply operation, defrosting starts automatically (for
approximately 2 to 10 minutes) to maintain the heating capacity.
• During the defrosting operation, the defrosted water will be drained from the bottom plate of the outdoor unit.
Heating capacity
In the heating operation, the heat is absorbed from the outside and brought into the room. This way of heating is
called heat pump system. When the outside temperature is too low, it is recommended to use another heating
apparatus in combination with the air to water heat pump.
Attention to snowfall and freeze on the outdoor unit
• In snowy areas, the air inlet and air outlet of the outdoor unit are often covered with snow or frozen up.
If snow or freeze on the outdoor unit is left as it is, it may cause machine failure or poor warming.
• In cold areas, pay attention to the drain hose so that it perfectly drains water without water remaining inside for
freeze prevention. If water freezes in the drain hose or inside the outdoor unit, it may cause machine failure or
poor warming.
Air to water heat pump operating conditions
For proper performance, operate the air to water heat pump under the following temperature conditions:
If air to water heat pump is used outside of the above conditions, safety protection may work.
Cooling operation
Outdoor temperature
: 10°C to 43°C
Room temperature
: 18°C to 32°C (Dry valve temp.)
Hot water
Outdoor temperature
: –20°C to 43°C
Room temperature
: 5°C to 32°C
Heating operation
Outdoor temperature
: –20°C to 25°C
Room temperature
: 5°C to 32°C
11-EN
Summary of Contents for ESTIA HWS-1102H-E
Page 3: ...2 1 INTRODUCTION ...
Page 7: ...6 2 SYSTEM OVERVIEW ...
Page 10: ...9 3 SYSTEM SPECIFICATION ...
Page 12: ...11 4 HYDRO UNIT ...
Page 44: ...43 5 OUTDOOR UNIT ...
Page 57: ...56 6 HOT WATER CYLINDER ...
Page 63: ...62 7 HYDRO UNIT INSTALLATION MANUAL ...
Page 107: ...105 8 OUTDOOR UNIT INSTALLATION MANUAL ...
Page 131: ...129 9 OWNER S MANUAL ...
Page 146: ...Air to Water Heat Pump Engineering Data Book Aug 2009 ...