6.HOT WATER CYLINDER
Engineering Data book
58
6
6-2. Dimension
General dimensions and performance
C
B
D
A
25°
30°
45°
45°
Ø550
29
MODEL
HWS-1501CSHM3-E
HWS-1501CSHM3-UK
HWS-2101CSHM3-E
HWS-2101CSHM3-UK
HWS-3001CSHM3-E
HWS-3001CSHM3-UK
NOMINAL CAPACITY
(litres)
150
210
300
A (mm)
315
315
315
B (mm)
354
354
354
C (mm)
800
1184
1474
D (mm)
1090
1474
2040
SURFACE AREA (sq.m)
0.65
0.79
0.79
HOT WATER OUTPUT
AT 60ºC (litres)
102
163
254
MIXED HOT WATER
OUTPUT AT 40ºC
(litres)
243
329.5
476
HEATLOSS (kWh/24h)
1.45
1.91
2.52
HEATING TIME 15ºC
TO 60ºC - USING
ELECTRIC CYLINDER
HEATER ONLY (mins)
123
188
262
CAPACITY HEATED
USING ELECTRIC
CYLINDER HEATER
ONLY (litres)
102
163
254