160
070 Line Error
128 lines
256 lines
512 lines
1024 line
2048 lines
Off
(will not disconnect line)
1. Selects the line disconnect condition during
reception. If the number of line errors exceed this
setting, the unit will disconnect the line.
Press “V” or “/\ “ to select the symbol rate.
2. Selects the transmit condition of RTP/PIP or
RTN/PIN.
(Available if No.73 Error Detect is set to "LINES")
(See Note 1)
071 Total Error
1 = 5%
2 = 10%
3 = 15%
4 = 20%
Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No.73 Error Detect is set to "RATE".)
(See Note 2)
072 Continuous Error 1 = Off (unlimited)
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
Selects the continuous total error criteria of Off/3/6
or 12 lines in Standard mode. If continuous total
error exceeds this setting, the unit will transmit
RTN/PIN.
(Available if No.73 Error Detect is set to "RATE".)
073 Error Detect
1 = Lines
2 = Rate
Selects the error detect condition Lines/Rate.
074 RTN Receive
1 = Disconnect
2 = Continue
Selects whether to disconnect the phone line or
continue when "RTN" is received.
075 Coding
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR
(MH or MR or MMR)
4 = JBIG
Selects the coding scheme.
076 Batch TX
1 = Off
2 = On
Selects whether the batch transmission is available.
077 RX JAM Length
1 = Off (unlimited)
2 = 2 m
Selects the maximum length of a received
document that can be printed.
078~
079
Not Used
080 Doc Top Feed
-99
~
+99
Adjusts the distance between the scanning sensor
ON position and the scanning start position.
081 Doc End Feed
-90
~
+127
Adjusts the distance between the scanning sensor
OFF position and the scanning end position.
082 JAM Length
1 = 1 m
2 = 2 m
Selects the maximum length of the original that can
be scanned.
083 Not Used
084 Line As No Paper 1 = Ring (ring)
2 = Busy (keep line busy)
Selects whether to ring or send a busy tone to the
remote station when the recording paper runs out or
the unit cannot receive because of any trouble.
085~
086
Not Used
087 Darker Level
0 = Lightest Contrast
~
15 = Darkest Contrast
Selects the contrast level.
0
←
→
15
Lightest
←
→
Darkest
088 Normal Level
089 Lighter Level
Function Parameter Table
No.
Parameter
Selections
Function
Summary of Contents for e-STUDIO190F
Page 5: ...5 ...
Page 21: ...21 1 2 Control Panel For Americas e STUDIO190F ...
Page 119: ...119 Sensor and Switch Location ...
Page 185: ...185 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Page 234: ...234 7 Installation Refer to Quick Guide For Facsimile and Copy Functions ...
Page 297: ...297 memo ...