73
Note:
1. Manual mode must be used, when updating the designated version of the firmware or changing
the type of the firmware.
Please refer to the Section 2.2, "
Setting up the Network Firmware Update Tool, File Selection
Tab
" of the Operating Instructions.
2. While updating the firmware code, the display may become garbled, however, it will return to
normal upon completion of the firmware update.
3. If the firmware update fails and the unit does not boot up, the Network Firmware Update Tool will
not be able to transfer the firmware code. If this occurs, please refer to the next section
"
Updating through the USB Port
" and use the Local Firmware Update Tool to recover the unit.
4. The suffix "_xx" for the Folder Name or File Name may not exist depending on the destination
location.
3.5.3.
Updating through USB Port (Alternate Method)
If the device is not connected to the LAN, upgrade the firmware code using the USB Port.
1) Install the Local Firmware Update Tool to your PC
The option CD-ROM includes the Local Firmware Update Tool and the Main Unit Firmware Code.
Please refer to the following Operating Instructions to install the Local Firmware Update Tool.
Operating Instructions:
\xFirmware\Tools\Firmup\FIRMUP OI.pdf (Refer to the
Local Firmware Update Tool OI
on the CD)
Setup:
\xFirmware\Tools\Firmup\Setup\Setup.exe
2) Preparing the Firmware Code
Double click the appropriate Destination Shortcut Batch File and copy the Firmware Code File on the
CD-ROM to the Firmware Data Folder in your PC. Note that the files in the Archive will be extracted
automatically into the designated folder when the Archived file (.exe) is Double-clicked.
Example:
From:
Destination Shortcut Batch File: D:(CD-ROM Drive) \ xFirmware \ USA.bat
Firmware Code File:
UF-8000_xx_xxxxxx.exe
To:
Firmware Data Folder:
C:\ Pcc \ Fup \ Data
3) Preparing the Main Unit for the Firmware Upgrade
Important: DO NOT connect the USB Cable yet.
Enter into Test Mode F9-07-01 to enable the unit to accept the programming code from the USB Port
by following the steps below.
1. Press "
FUNCTION
", "
ORIGINAL SIZE
" keys and then Key "
3
" on the keypad sequentially to enter
Test Mode.
Note:
Press "
FUNCTON
" and "
CLEAR
" keys sequentially to exit Test Mode.
2. Press "
9
" and "
START
" keys.
3. Press "
7
" and "
SET
" keys.
4. Press "
1
" and "
SET
" keys.
5. Press "
SET
" key.
Now connect the USB Cable between the Unit and PC.
Repeat the above steps if there are additional firmware code files to be updated.
06/08
Summary of Contents for e-STUDIO190F
Page 5: ...5 ...
Page 21: ...21 1 2 Control Panel For Americas e STUDIO190F ...
Page 119: ...119 Sensor and Switch Location ...
Page 185: ...185 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Page 234: ...234 7 Installation Refer to Quick Guide For Facsimile and Copy Functions ...
Page 297: ...297 memo ...
Page 299: ...299 memo ...