123
400
XMT
B
T1 timer (35 ± 5 sec.) elapsed
without detecting 300 bps signal.
Incorrect number was dialed and the
START button was pushed.
Telephone line was disconnected while
dialing.
SC PCB or FXB PCB is defective.
Receiver is defective. (It may only be
transmitting CED)
401
XMT
B
DCN was returned from receiver
while transmitter is waiting for CFR
or FTT.
Your machine's ID Number is not
programmed.
Possible incompatibility or incorrect
Password.
402
XMT
B
DCN was returned from receiver
while transmitter is waiting for
NSF/DIS.
Receiver working in non-ITU mode only.
(Possible incompatibility)
403
RCV
(Polling)
B
Transmitter had no polling
function.
"POLLED=ON" (polling XMT ready) is
not set at the transmitter.
Document to be transmitted is not
placed at the transmitter.
404
XMT
B
Transmitter sent NSS (or DCS)
followed by TCF three times, but
the receiver did not respond. (CFR
or FTT is usually returned)
Receiver is defective. (Modem)
SC PCB or FXB PCB is defective.
Receiver disconnects line during first
NSS (or DCS) is transmitted.
405
XMT
B
Transmitter received FTT after it
transmitted TCF at 2400bps.
Received RTN after
communicating at 2400 bps.
Line quality is poor. (TCF is damaged
due to line noise)
Receiver is defective. (Modem, etc.)
SC PCB or FXB PCB is defective.
406
RCV
(Password
Comm.)
B
XMT-Password mismatched.
RCV-Password mismatched.
Selective RCV incomplete.
XMT, RCV password does not match.
Last 4 digits of TSI does not match with
the last 4 digits of ONE-TOUCH, ABBR
telephone number.
407
XMT
D
Transmitter received no response
after it transmitted post message,
such as EOP, MPS, EOM, etc...or
received DCN.
Receiver is defective. (No paper, paper
jamming, etc.)
Receiver ceased receiving because of
excessive error. (Line quality is poor)
SC PCB or FXB PCB is defective.
408
XMT
D
Transmitter received RTN after it
transmitted EOP, MPS, or EOM.
Receiver receives data with error. (Line
quality is poor)
Receiver is defective. (Modem, etc.)
SC PCB or FXB PCB is defective.
409
XMT
D
Transmitter receives PIN after it
transmitted a post message, such
as EOP, MPS, EOM, etc.
Receiver receives data with error due to
poor line quality, and receiving operator
requests voice contact.
Receiver is defective. (Modem, etc.)
SC PCB or FXB PCB is defective.
410
RCV
D
Received DCN while waiting for
post command. (EOP, MPS, EOM,
etc.)
Interface or line is faulty.
Transmitter is defective.
411
RCV
(Polling)
B
Received DCN after transmitting
NSC.
Transmitter is not ready for polling
communication.
Password does not match between
transmitter and receiver.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Summary of Contents for e-STUDIO190F
Page 5: ...5 ...
Page 21: ...21 1 2 Control Panel For Americas e STUDIO190F ...
Page 119: ...119 Sensor and Switch Location ...
Page 185: ...185 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Page 234: ...234 7 Installation Refer to Quick Guide For Facsimile and Copy Functions ...
Page 297: ...297 memo ...
Page 299: ...299 memo ...