67
3.2.
Required Tools
3.2.1.
Preventive Maintenance Method
No.
Tools
No.
Tools
1
Soft Cloth
7
Pliers
2
Isopropyl Alcohol
8
Cotton Swab
3
Phillips Screwdriver (#2)
9
Brush
4
Stubby Phillips Screwdriver (#2)
10
KS-660 - Conductive Grease
(Available from Shin-Etsu Silicones of America, Inc.
URL:
http://www.shinetsusilicones.com
)
5
Slotted Screwdriver (3/32 in)
11
Molykote EM-50L Grease
(Available from Dow Corning,
URL:
http://www.dowcorning.com
)
6
Tweezer
No.
Part Description
Important
Action
Comments
1
Memory Data
Check
1. Print the RAM DATA for reference and as a precaution.
2. After completing the task(s), print and compare the RAM
DATA with the previously printed one.
2
Auto Document
Feeder (ADF)
Check &
Clean
1. Clean the Rollers with Wet soft cloth (Water).
Note:
For stubborn toner accumulation, wipe with a soft cloth
saturated with Isopropyl Alcohol first, then follow up with
a soft cloth saturated with water.
3
Scanner Unit
Check &
Clean
1. Clean the Scanning Glass or White Reference Sheet with
Isopropyl Alcohol when required.
2. Clean it with Wet soft cloth.
4
Transmitter Unit
Check &
Clean
1. Remove any foreign obstacles.
2. Clean the Rollers with Wet soft cloth (Water).
5
Inspection Items
Check
1. Check the Harnesses.
2. Check the Connectors.
3. Check the Screws. If required, replace consumable parts.
6
Gears, Rollers Shafts
Check &
Grease
1. Check and grease the required Gears and Shafts.
7
Timing Belts
Check &
Clean
1. Check for belt looseness or abrasion.
2. Adjust the Idle Pulley.
Summary of Contents for e-STUDIO190F
Page 5: ...5 ...
Page 21: ...21 1 2 Control Panel For Americas e STUDIO190F ...
Page 119: ...119 Sensor and Switch Location ...
Page 185: ...185 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Page 234: ...234 7 Installation Refer to Quick Guide For Facsimile and Copy Functions ...
Page 297: ...297 memo ...
Page 299: ...299 memo ...