4.3.4.
Ghost Images
START
END
No
Yes
Check the Scanner mechanism.
Is the Toner Cartridge
operational?
No
Yes
Are the Fuser and Pressure
Roller surfaces clean?
No
Yes
Is the recording paper damp?
Are there any foreign particles
or stains on the BTR?
No
Yes
Yes
No
Replace the recording paper.
Replace the Toner Cartridge.
1. Clean the BTR with a soft,
dry cloth.
2. Replace the BTR.
Clean or replace the rollers.
Paper Travel
A
A
A A A
Is the printout in Service
Mode 3 normal?