127
718
XMT
LAN
Page Memory Overflow occurred
while receiving printing data. The
paper size selected within your
application to print is larger than
the paper size loaded in the
Tray(s).
Check the document size and
resolution.
Ask originator to re-send in a supported
size and resolution.
719
RCV
LAN
Received data via LAN is in a
format that is not supported.
Ask the originator to re-send with a
supported file attachment:
* In a TIFF-F format.
* Image data conforming to A4/Letter
size.
720
POP
LAN
Unable to connect with the POP
Server.
Incorrect POP Server Address is set.
POP Server is down.
721
POP
LAN
Unable to login to the POP Server. Incorrect User Name or Password is
set.
722
RCV
LAN
Failed to obtain the Network
Parameters (such as: IP Address,
Subnet Mask, Default Gateway IP
Address, etc.) from the DHCP
server.
LAN Cable is disconnected.
DHCP is not available.
(Contact the Network Administrator.)
725
XMT
POP
LAN
DNS Server connection timed out. Incorrect DNS Server Address is set.
DNS Server is down.
726
XMT
POP
LAN
Received an error response from
the DNS Server.
Incorrect POP Server Address is set.
Incorrect SMTP Server Address is set.
727
XMT
LAN
Received an Error or No
Response from the Remote
Internet Fax. (SMTP Direct XMT)
Remote Internet Fax Errors: Busy or
Job Number Overflow for Relay XMT.
(Retry is possible)
728
XMT
LAN
Remote Internet Fax Errors: Memory
Overflow or No Power.
(Retry is not possible)
729
XMT
LAN
Failed to authenticate (SMTP
AUTHENTICATION) when
connecting with the SMTP server.
SMTP AUTHENTICATION, User Name
and/or Password are incorrect.
(Contact the Network Administrator.)
730
RCV
LAN
Unable to program the Internet
parameters or the autodialer via
Email from a PC.
Verify that the Fax Parameter #158 is
set to Valid.
731
RCV
LAN
Dialer full while Relayed
Transmission Request was
received.
Dial buffer for manual number dialing
(70 stations) is being used.
741 XMT, Polling PSTN Unable to dial
Deleted the registered station name
before dialing with Timer Controlled
Communications, etc.
800
Relay
Comm.
PSTN The machine was requested to
relay a document but has no Relay
Hub capability.
814
Conf. XMT
Conf. Polling
Relay
Comm.
PSTN The remote station does not have
Relay XMT nor Confidential
Communication capability.
815
Conf. RCV
PSTN Mailbox full.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Summary of Contents for e-STUDIO190F
Page 5: ...5 ...
Page 21: ...21 1 2 Control Panel For Americas e STUDIO190F ...
Page 119: ...119 Sensor and Switch Location ...
Page 185: ...185 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Page 234: ...234 7 Installation Refer to Quick Guide For Facsimile and Copy Functions ...
Page 297: ...297 memo ...
Page 299: ...299 memo ...