e-STUDIO165/167/205/207/237
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 50
433-0
Fuser
Temperature
control lower
limit
(Plain paper/
at ordinary
temperature)
Center
thermistor
ALL
16 cpm /
20 cpm:
5
23 cpm:
6
<0-12>
M
0: 130°C 1: 135°C
2: 140°C 3: 145°C
4: 150°C 5: 155°C
6: 160°C 7: 165°C
8: 170°C 9: 175°C
10: 180°C
11: 185°C
12: 120°C
2
433-1
Side ther-
mistor
ALL
16 cpm /
20 cpm:
3
23 cpm:
4
<0-12>
M
2
437
Fuser
Fuser roller temperature
during printing
(Center thermistor /Thick
paper 2)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
438
Fuser
Fuser roller temperature
during printing
(Center thermistor/OHP
film)
ALL
6
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
439
Fuser
Pre-running time for first
printing
(Thick paper 2)
ALL
10
<0-15>
M
0: Invalid 1: 1 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
1
440
Fuser
Pre-running time for first
printing
(Plain paper)
ALL
0
<0-15>
M
0: Invalid 1: 1 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
07/02
Summary of Contents for e-STUDIO165
Page 8: ...e STUDIO165 167 205 207 237 2006 2008 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 10: ......
Page 312: ......
Page 313: ......